NEXIVA 20GA 1.25IN HF Y
Report
- Report Number
- 1710034-2021-00140
- Event Type
- Malfunction
- Date Received
- February 24, 2021
- Date of Event
- January 28, 2021
- Report Date
- March 29, 2021
- Manufacturer
- BECTON DICKINSON INFUSION THERAPY SYSTEMS INC.
- Product Code
- FOZ
- UDI-DI
- 00382903835379
- PMA / PMN Number
- K183399
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D.10. DEVICE AVAILABLE FOR EVAL?: YES. D.10. RETURNED TO MANUFACTURER ON: 2/16/2021. H.6. INVESTIGATION: OUR QUALITY ENGINEER INSPECTED THE SAMPLES AND PHOTOGRAPHS SUBMITTED FOR EVALUATION. BD RECEIVED ELEVEN UNOPENED UNITS AND SEVEN PHOTOS. DURING THE VISUAL EXAMINATION OF THE UNITS AND PHOTOS, IT WAS OBSERVED THAT EXCESS MATERIAL AND SHARP EDGES WERE PRESENT CONFIRMING THE REPORTED DEFECT. MISALIGNMENT OR INCORRECT SETUP DURING THE CUTTING PROCESS MAY RESULT IN EXCESS MATERIAL LIKE THAT OBSERVED IN THE RETURNED UNITS RESULTING IN SHARP EDGES; THEREFORE, THE MOST PROBABLE ROOT CAUSE IS MANUFACTURING. THE SEAL WIDTH WAS MEASURED TO DETERMINE IF A SUFFICIENT SEAL WAS MADE. ALL ELEVEN SEALS WERE FOUND TO BE WITHIN SPECIFICATION INDICATING THAT THE STERILITY WAS NOT AFFECTED BY THE DEFECT. A DEVICE HISTORY RECORD REVIEW SHOWED NO NON-CONFORMANCES ASSOCIATED WITH THIS ISSUE DURING THE PRODUCTION OF THIS BATCH.
IT WAS REPORTED THAT NEXIVA 20GA 1.25IN HF Y PACKAGE WAS DAMAGED. THIS OCCURRED ON 11 OCCASIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THIS IS A REPORT ABOUT DAMAGED PACKAGES. ACCORDING TO THE CUSTOMER'S REPORT, THE PACKAGE COMPONENT (PLASTIC TRAY) WAS DAMAGED (DEFORMED) IN 11 OF 20 PRODUCTS. (ADDITIONAL INFORMATION ON 02/03/2021) THE PERIPHERY OF THE PACKAGE TRAY WAS PARTLY DEFORMED SHARPLY (UPPER PART) OR CUT DIAGONALLY (LOWER PART) AND THE CUSTOMER IS QUESTIONING WHETHER STERILIZATION OF THE PACKAGE HAS BEEN GUARANTEED.
A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED. (B)(4).
IT WAS REPORTED THAT NEXIVA 20GA 1.25IN HF Y PACKAGE WAS DAMAGED. THIS OCCURRED ON 11 OCCASIONS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THIS IS A REPORT ABOUT DAMAGED PACKAGES. ACCORDING TO THE CUSTOMER'S REPORT, THE PACKAGE COMPONENT (PLASTIC TRAY) WAS DAMAGED (DEFORMED) IN 11 OF 20 PRODUCTS. (ADDITIONAL INFORMATION ON 02/03/2021). THE PERIPHERY OF THE PACKAGE TRAY WAS PARTLY DEFORMED SHARPLY (UPPER PART) OR CUT DIAGONALLY (LOWER PART) AND THE CUSTOMER IS QUESTIONING WHETHER STERILIZATION OF THE PACKAGE HAS BEEN GUARANTEED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 272334 | NEXIVA 20GA 1.25IN HF Y | INTRAVASCULAR CATHETER | FOZ | BECTON DICKINSON INFUSION THERAPY SYSTEMS INC. | 0168884 | 00382903835379 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |