FDA Adverse Event Injury Summary report: N

STEM: AMISTEM C CEMENTED STD STEM SIZE 3

MDR report key: 11337496 · Received February 17, 2021

Report

Report Number
3005180920-2021-00118
Event Type
Injury
Date Received
February 17, 2021
Date of Event
January 15, 2021
Report Date
February 17, 2021
Manufacturer
MEDACTA INTERNATIONAL SA
Product Code
LZO
UDI-DI
07630030804281
PMA / PMN Number
K103189
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 1

BATCH REVIEW PERFORMED ON 15.FEBRUARY.2021: LOT 2002911: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 10-AUG-2020. EXPIRATION DATE: 2025-07-05. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED EVENT. ADDITIONAL IMPLANT INVOLVED: CUP: MPACT 01.32.152MB DOUBLE MOBILITY ACETABULAR SHELL Ø52 (K143453) LOT. 2000204. BATCH REVIEW PERFORMED ON 15.FEBRUARY.2021: LOT 2000204: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 1-JUL-2020. EXPIRATION DATE: 2025-06-23. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED EVENT. ADDITIONAL IMPLANT INVOLVED: BALL HEADS: MECTACER 01.29.202 BIOLOX DELTA CERAMIC BALL HEAD 12/14 Ø 28 SIZE M 0 (K112115) LOT. 165965 BATCH REVIEW PERFORMED ON 15.FEBRUARY.2021: LOT 165965: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 10-JAN-2017. EXPIRATION DATE: 2021-12-19. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITH ONE SIMILAR REPORTED EVENT. ADDITIONAL IMPLANT INVOLVED: LINER: VERSAFITCUP DM 01.26.2852MHC DOUBLE MOBILITY HC LINER 28/DMF (K092265) LOT. 2001457. BATCH REVIEW PERFORMED ON 15.FEBRUARY.2021: LOT 2001457: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 23-JUN-2020. EXPIRATION DATE: 2025-06-02. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITH ONE SIMILAR REPORTED EVENT.

Description of Event or Problem · 1

THE PATIENT CAME IN 1 MONTH AFTER THE PRIMARY SURGERY DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED ALL COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
233309 STEM: AMISTEM C CEMENTED STD STEM SIZE 3 CEMENTED HIP STEM LZO MEDACTA INTERNATIONAL SA 01.18.153 2002911 07630030804281

Patients

Seq Age Sex Outcome Treatment
1