BD NEXIVA CLOSED IV CATHETER SYSTEM
Report
- Report Number
- 9610847-2021-00003
- Event Type
- Malfunction
- Date Received
- January 8, 2021
- Date of Event
- December 3, 2020
- Report Date
- February 10, 2021
- Manufacturer
- BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
- Product Code
- FOZ
- UDI-DI
- 30382903835561
- PMA / PMN Number
- K183399
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
H6: INVESTIGATION SUMMARY OUR QUALITY ENGINEER INSPECTED THE SAMPLES AND PHOTOGRAPHS SUBMITTED FOR EVALUATION. BD RECEIVED NINETEEN UNOPENED SHIPPER BOXES (B)(4) UNITS IN TOTAL) FROM THE DISTRIBUTOR (OWENS & MINOR) TO BE INVESTIGATED UNDER PR¿S 2090830, 2105563, 2120568, 2135578, AND 2137283. TWO OPENED UNITS AND SIX PHOTOS WERE ALSO RECEIVED. SINCE THE NINETEEN BOXES OF UNITS WERE UNUSED, SEVENTY-SIX UNITS WERE RANDOMLY SELECTED FOR TESTING PER BD POLICY. THE UNITS WERE VISUALLY INSPECTED FOR ANY SIGNS OF DAMAGE TO THE TIP SHIELD, V-CLIP, AND ADAPTER PRIOR TO DECOUPLE. NO VISUAL DEFECTS WERE OBSERVED IN THE SEVENTY-SIX UNITS AND NO UNITS WERE FOUND TO HAVE PREMATURELY DECOUPLED. THE UNITS WERE THEN RETRACTED TO CHECK FOR FAILURE TO DECOUPLE. ONE UNIT FAILED TO DECOUPLE. NO UNITS WERE FOUND TO HAVE AN EXPOSED NEEDLE. DURING THE MICROSCOPIC EXAMINATION OF THE FAILED UNIT, IT WAS OBSERVED THAT DEFORMED PLASTIC FROM THE TIP SHIELD WAS PREVENTING THE V-CLIP FROM MOVING TO THE OPEN POSITION. THIS IN TURN PREVENTED THE NEEDLE ASSEMBLY FROM DECOUPLING FROM THE WINGED ADAPTER. BASED ON THE LOCATION OF THE DAMAGE, THE DEFECT MOST LIKELY ORIGINATED DURING THE MANUFACTURING PROCESS. AN ADDITIONAL SEVEN UNITS WERE ALSO FOUND TO HAVE DAMAGE TO THE TIP SHIELD. HOWEVER, THE PLASTIC DID NOT INTERFERE WITH DECOUPLING. UPON INITIAL INSPECTION OF THE TWO OPENED UNITS, IT WAS IDENTIFIED THAT ONE UNIT WAS COMPLETELY RETRACTED BUT HAD NOT DECOUPLED FROM THE WINGED ADAPTER AND THE OTHER UNIT COULD BE PULLED STRAIGHT OFF THE WINGED ADAPTER WITHOUT PERFORMING RETRACTION. FURTHER INSPECTION OF THE OPENED UNIT THAT HAD NOT DECOUPLED REVEALED THAT THE SAME DAMAGE TO THE TIP SHIELD THAT WAS FOUND IN THE UNOPENED UNIT WAS ALSO PREVENTING THIS UNIT FROM DECOUPLING. THE SECOND OPENED UNIT WAS FURTHER INSPECTED AND FOUND TO HAVE DAMAGE WHICH PREVENTED THE TIP SHIELD FROM LATCHING ONTO THE BASE. THIS DAMAGE LIKELY OCCURRED DURING MANUFACTURING. THE PROVIDED PHOTOS WERE INSPECTED AND DETERMINED TO DISPLAY THE SAME DEFECTS OBSERVED IN THE TWO OPENED UNITS THAT WERE RECEIVED. THE FAILURES OF FAILURE TO DECOUPLE AND PREMATURE DECOUPLING WERE CONFIRMED THROUGH THE INVESTIGATION. BD WAS ABLE TO IDENTIFY THE ROOT CAUSES AS MOST LIKELY ORIGINATING DURING MANUFACTURING. A DEVICE HISTORY RECORD REVIEW WAS PERFORMED FOR THIS BATCH. AS THE ROOT CAUSE WAS DETERMINED TO BE MANUFACTURING RELATED. SEE H10.
IT WAS REPORTED THAT THE BD NEXIVA¿ CLOSED IV CATHETER SYSTEM NEEDLE WAS DIFFICULT TO DISENGAGE AND THE SAFETY MECHANISM GOT STUCK. THIS COMPLAINT WAS CREATED TO CAPTURE THE 3RD OF 3 RELATED INCIDENTS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "20G IV CATHETER (LOT #0014645) WAS PERIPHERALLY INSERTED IN PATIENTS LEFT FOREARM BY RN. UPON RETRACTING THE NEEDLE, THE NEEDLE WOULD NOT DISCONNECT FROM THE PLASTIC CATHETER THAT STAYS IN THE PATIENT. ASKED ANOTHER RN, TO TRY AND DISCONNECT THE NEEDLE AND WERE UNSUCCESSFUL. THE PATIENT HAD TO HAVE THAT IV DISCONTINUED AND ANOTHER ONE PLACED."
A DEVICE EVALUATION IS ANTICIPATED BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED. (B)(4).
IT WAS REPORTED THAT THE BD NEXIVA¿ CLOSED IV CATHETER SYSTEM NEEDLE WAS DIFFICULT TO DISENGAGE AND THE SAFETY MECHANISM GOT STUCK. THIS COMPLAINT WAS CREATED TO CAPTURE THE 3RD OF 3 RELATED INCIDENTS. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "20G IV CATHETER (LOT #(B)(4)) WAS PERIPHERALLY INSERTED IN PATIENTS LEFT FOREARM BY RN. UPON RETRACTING THE NEEDLE, THE NEEDLE WOULD NOT DISCONNECT FROM THE PLASTIC CATHETER THAT STAYS IN THE PATIENT. ASKED ANOTHER RN, TO TRY AND DISCONNECT THE NEEDLE AND WERE UNSUCCESSFUL. THE PATIENT HAD TO HAVE THAT IV DISCONTINUED AND ANOTHER ONE PLACED."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 38296 | BD NEXIVA CLOSED IV CATHETER SYSTEM | INTRAVASCULAR CATHETER | FOZ | BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. | 383556 | 0014645 | 30382903835561 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |