FDA Adverse Event Other Summary report: N

INFINITY DELTA

MDR report key: 1113604 · Received August 14, 2008

Report

Report Number
1220063-2008-00026
Event Type
Other
Date Received
August 14, 2008
Date of Event
July 5, 2008
Report Date
August 7, 2008
Manufacturer
DRAEGER MEDICAL SYSTEMS, INC.
Product Code
DSI
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

BASED ON ALL INFO RECEIVED, DRAEGAR MEDICAL HAS NOT FOUND ANY EVIDENCE TO CONCLUDE THAT THE MONITOR WAS NOT PERFORMING AS INTENDED. OUR EVALUATION HAS CONFIRMED THAT THE ADVERSE EVENT REPORTED IS NOT A RESULT OF A DRAEGER MEDICAL DEVICE FAILURE. THE HOSPITAL BIOMEDS CHECKED THE MONITOR RIGHT AFTER THE PT EXPIRED WITH A BP SIMULATOR AND IT WAS ACCURATE. IN ADDITION, DRAEGER MEDICAL CHECKED THE MONITOR ON JULY 8, 2008 USING THE BP STIMULATOR AND DID SEVERAL VERY LOW BP'S AND SEVERAL VERY HIGH BP'S AND ALL READINGS WERE FOUND ACCURATE.

Description of Event or Problem · 1

DRAEGER MEDICAL SYSTEMS, INC. RECEIVED INFO FROM OUR OFFICE IN (B) (4) THAT INCLUDES THE FOLLOWING CUSTOMER REPORT: INFO WITHIN THE NURSES NOTES STATED THAT "HEMODIALYSIS WAS STARTED ON THE PT INVOLVED, AROUND 1700 HOURS. AT APPROX THAT TIME, THE POSITION ART LINE STOPPED GIVING A READING. THE PT WAS ON 3 DIFFERENT INOTROPE DRUGS AT THE TIME. ONCE THE ART LINE GAVE WAY, HOSPITAL STAFF RELIED ON NIBP READINGS TO TITRATE DRUGS. WITH BP READINGS IN THE 200'S, THE STAFF DECREASED THE INOTROPE DRIPS OVER THE NEXT FEW HOURS, RESTARTING THE DRIPS WHENEVER BP READINGS DROPPED. AT 2115, AN INACCURATE NIBP OF 251/57 WAS NOTED WHEN STAFF MANUALLY MEASURED SBP OF LESS THAN 90 (ALL 3 DRIPS WERE REPORTED MAXED OUT AT THIS POINT). AT 2125 THE NIBP READ 200/72 AND THE STAFF BEGAN REDUCING THE INOTROPES (DESPITE HAVING NOTED THAT THE NIBP WAS INACCURATE 10 MINUTES BEFORE WITH A SBP OF 251). THEREAFTER, THE INOTROPES WERE CONTINUALLY REDUCED FOR A NIBP OF 192/30. AT 2220, IT WAS NOTED THAT BP WAS IMMEASURABLE VIA NIBP. AT 2222, NIBP READ 221/34 BUT A MANUAL CHECK OF BP SHOWED A SYSTOLIC OF <50. AT 2231 IT WAS AGAIN NOTED THAT THE NIBP READINGS WERE INACCURATE, MANUAL SBP WAS NOTED AT <90. THE PT EXPIRED AROUND 0400. THE HOSP BIOMEDS CHECKED THE MONITOR RIGHT AFTER THE PT EXPIRED WITH A BP STIMULATOR AND IT WAS ACCURATE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1 INFINITY DELTA PATIENT MONITOR DSI DRAEGER MEDICAL SYSTEMS, INC. 5398435450

Patients

Seq Age Sex Outcome Treatment
1 Death