FDA Adverse Event Injury Summary report: N

V680 VENTILATOR

MDR report key: 11091306 · Received December 29, 2020

Report

Report Number
2031642-2020-04772
Event Type
Injury
Date Received
December 29, 2020
Date of Event
December 20, 2020
Report Date
December 22, 2020
Manufacturer
RESPIRONICS CALIFORNIA, INC
Product Code
CBK
UDI-DI
00884838053595
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

B3: 30DEC2020. B4: 30DEC2020. CORRECTION: THE V680 IS AN EXPORTED DEVICE AND NOT AVAILABLE FOR COMMERCIAL DISTRIBUTION IN THE UNITED STATES, THEREFORE DOES NOT FALL WITHIN FDA REPORTING GUIDELINES. SUBMISSION OF A REPORT DOES NOT CONSTITUTE AN ADMISSION THAT MEDICAL PERSONNEL, USER FACILITY, IMPORTER, DISTRIBUTOR, MANUFACTURER, OR PRODUCT CAUSED OR CONTRIBUTED TO THE EVENT.

Additional Manufacturer Narrative · 1

EVENT DATE: (B)(6) 2020. REPORT DATE: 29DEC2020.

Description of Event or Problem · 1

A CUSTOMER REPORTED TO PHILIPS THAT WHILE DELIVERING THERAPY TO A PATIENT, THE RESPIRONICS V680 VENTILATOR BECAME DISCONNECTED FROM THE PATIENT, DID NOT GENERATE AN ALARM, AND THE PATIENT REQUIRED MANUAL VENTILATION. THE CUSTOMER REPORTED THAT THE UNIT WAS IN USE ON A PATIENT AT THE TIME OF THE REPORTED DEVICE BEHAVIOR AND MEDICAL INTERVENTION. THIS REPORTER STATED THAT A PATIENT OF UNKNOWN AGE, GENDER, HEIGHT, AND WEIGHT WAS ADMITTED TO A HOSPITAL ON AN UNKNOWN DATE WITH THE ADMITTING DIAGNOSIS NOT REPORTED. NO RELEVANT MEDICAL HISTORY, RELEVANT PAST DRUG HISTORY OR RELEVANT CONCOMITANT MEDICAL PRODUCTS WERE REPORTED. WHILE ADMITTED ON AN UNKNOWN DATE, THE PATIENT WAS PRESCRIBED VENTILATION THERAPY VIA THE RESPIRONICS V680 VENTILATOR; PRESCRIPTION, DEVICE SETTINGS, CONFIGURATION, PATIENT CIRCUIT, AND PATIENT INTERFACE NOT REPORTED. WHILE ADMITTED ON (B)(6) 2020 AT APPROXIMATELY 1000, THE PATIENT WAS RECEIVING THERAPY VIA THE V680 DEVICE, THE PATIENT BECAME DISCONNECTED FROM THE DEVICE, THE DEVICE DID NOT GENERATE ANY AUDIBLE ALARMS, HOSPITAL STAFF ADMINISTERED MANUAL VENTILATION, AND THE PATIENT WAS THEN RECONNECTED TO THE V680 VENTILATOR. NO RELEVANT LABORATORY DATA WAS REPORTED. POST EVENT, THE HOSPITAL'S BIOMEDICAL ENGINEER REVIEWED THE DEVICE'S DIAGNOSTIC REPORT (DRPT), AND REPORTED THAT THE DEVICE GENERATED SEVERAL PATIENT DISCONNECT ALARMS DURING THE EVENT. NO ADVERSE EVENT WAS REPORTED OR ASSOCIATED WITH THE USE OF THIS DEVICE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1556910 V680 VENTILATOR VENTILATOR, CONTINUOUS, FACILITY USE PRODUCT CODE: CBK CBK RESPIRONICS CALIFORNIA, INC V680 00884838053595

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention UNKNOWN PATIENT CIRCUIT, MASK, AND HUMIDIFIER