IMPL TAPERED SCR-V MTX 3.7MM 3.5MM 11.5MM
Report
- Report Number
- 0002023141-2020-02418
- Event Type
- Injury
- Date Received
- December 29, 2020
- Date of Event
- November 27, 2019
- Report Date
- April 7, 2021
- Manufacturer
- ZIMMER DENTAL
- Product Code
- DZE
- UDI-DI
- 00889024019515
- PMA / PMN Number
- K061410
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- SP
- Reporter Occupation
- DENTIST
Narratives
ZIMMERBIOMET COMPLAINT NUMBER: (B)(4). THE FOLLOWING SECTIONS HAVE BEEN UPDATED: B4: DATE OF THIS REPORT. B5: DESCRIBE EVENT OR PROBLEM. G3: DATE RECEIVED BY MANUFACTURER. H1: TYPE OF REPORT, FOLLOW-UP NUMBER. H2: FOLLOW UP TYPE. H3: DEVICE EVALUATED BY MANUFACTURER: CHANGE ¿NO' TO 'YES'. H6: EVALUATION CODES. H10: ADDITIONAL NARRATIVE. ONE (1) IMPL TAPERED SCR-V MTX 3.7MM 3.5MM 11.5MM (TSVB11) WAS RETURNED FOR INVESTIGATION (IMAGE ATTACHED IN COMPLAINT). VISUAL EVALUATION OF THE AS RETURNED PRODUCT IDENTIFIED NO APPARENT MALFUNCTION. SIGNS OF USE AND BONE PIECES ON THE EXTERNAL THREADS ONLY. PRODUCT MATCHED PRINT SPECIFICATION WHERE MEASURED. FUNCTIONAL TESTING TO RECREATE THE REPORTED EVENT COULD NOT BE PERFORMED DUE TO THE NATURE OF THE DEVICE & EVENT. A PRE-EXISTING CONDITION NOTED ON THE PER WAS LOW BONE DENSITY (TYPE III). THE REPORTED DEVICE WAS LOCATED ON TOOTH # 14 (UNIVERSAL) AND WAS IMPLANTED AND REMOVED ON THE SAME DAY. THE CUSTOMER DID NOT PROVIDE ANY PICTURES OR X-RAYS. REVIEW OF APPROPRIATE DOCUMENTATION: DOCUMENTS REVIEWED: (B)(4) REV 9-10/2019; ADVERSE EFFECTS; PAGE 2. DHR REVIEW WAS COMPLETED FOR THE SUBJECT LOT NUMBER: (1221637). IT WAS CONFIRMED THAT ALL OPERATIONS AND INSPECTIONS WERE EXECUTED AS PER APPLICABLE PROCEDURE. NO DEVIATIONS OR NON-CONFORMANCES, WHICH COULD HAVE CAUSED OR CONTRIBUTED TO THE REPORTED EVENT WAS NOTED AS PART OF THE DHR. LOT WAS INSPECTED AND PASSED ALL ACCEPTANCE CRITERIA BY QA. COMPLAINT HISTORY REVIEW WAS PERFORMED FOR THE REPORTED LOT NUMBER: (1221637) FOR SIMILAR EVENTS AND NO OTHER COMPLAINT WAS IDENTIFIED. JANUARY POST MARKET TRENDING WAS REVIEWED AND THERE WERE NO ACTIONABLE EVENTS OR CORRECTIVE ACTIONS FOR THE REPORTED EVENT (BONE FRACTURE) OR PRODUCT (TSVB11). NO ACTIONABLE ITEMS HAVE BEEN TRIGGERED THAT WILL AFFECT COMPLAINT HANDLING ON OUR END FOR THIS MONTH. THEREFORE, BASED ON THE AVAILABLE INFORMATION, DEVICE MALFUNCTION HAS NOT OCCURRED AND THE REPORTED EVENT IS NON-VERIFIABLE.
NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.
ZIMMERBIOMET COMPLAINT NUMBER (B)(4). PMA/510(K) NUMBERK013227.
IT WAS REPORTED DURING THE PROCEDURE WHILE DOCTOR WAS PLACING THE IMPLANT THE VESTIBULAR WALL FRACTURED. THE IMPLANT WAS REMOVED. DOCTOR PERFORMED BONE GRAFT (XENOGRAFT).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1553942 | IMPL TAPERED SCR-V MTX 3.7MM 3.5MM 11.5MM | DENTAL IMPLANT | DZE | ZIMMER DENTAL | TSVB11 | 1221637 | 00889024019515 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 39 YR | Required Intervention |