TAXUS EXPRESS2 PACLITAXEL-ELUTING CORONARY STENT SYSTEM
Report
- Report Number
- 2134265-2008-02236
- Event Type
- Injury
- Date Received
- August 7, 2008
- Date of Event
- March 7, 2008
- Report Date
- July 11, 2008
- Manufacturer
- BOSTON SCIENTIFIC
- Product Code
- NIQ
- PMA / PMN Number
- P030025
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
AS THE UNIT HAS NOT BEEN RETURNED, THE COMPLAINT INVESTIGATION SITE (CIS) COULD NOT PERFORM A TECHNICAL ANALYSIS. STENT THROMBOSIS IS A KNOWN COMPLICATION OF STENT IMPLANTATION WHICH HAS BEEN REPORTED FOR DRUG ELUTING STENTS. THE POTENTIAL ROOT CAUSES WERE REVIEWED. THE RESULT OF THIS REVIEW INDICATED THAT THE CURRENT MFG PROCESS CONTROLS TO PREVENT THIS FAILURE FROM OCCURRING WERE DEEMED ADEQUATE. A REVIEW OF THE MFG DOCUMENTATION COULD NOT BE PERFORMED AS THE BATCH NUMBER IS UNK. THE MOST PROBABLE ROOT CAUSE CLASSIFICATION OF ANTICIPATED PROCEDURAL COMPLICATION.
TAXUS EXPRESS2 CLINICAL STUDY. SAME CASE AS 2134265-2008-02230. IT WAS REPORTED THAT 2 DAYS AFTER A CORONARY DRUG ELUTING STENTING TREATMENT PROCEDURE, THE PT EXPERIENCED A MYOCARDIAL INFARCTION (MI), STENT THROMBOSIS (ST) AND REQUIRED A TARGET VESSEL REINTERVENTION (TVR). LESION 1 WAS A 3.0MM, 90% STENOSED, 32MM LONG PORTION OF THE PROXIMAL RIGHT CORONARY ARTERY (PROX RCA). THE PHYSICIAN TREATED THE LESION WITH PREDILATATION AND SUCCESSFUL PLACEMENT OF A TAXUS EXPRESS2 3.00X32MM STUDY STENT IN THE TARGET LESION. POST DILATED WITH THE SAME BALLOON USED FOR PRE-DILATATION AND ANOTHER BALLOON 2.75-15MM AT 20 ATM. LESION 2 WAS A 2.75MM, 90% STENOSED, 32MM LONG PORTION OF THE MID RIGHT CORONARY ARTERY (MID RCA). THE PHYSICIAN TREATED THE LESION WITH PREDILATATION AND SUCCESSFUL PLACEMENT OF A TAXUS EXPRESS2 2.75X32MM STUDY STENT IN THE TARGET LESION. POST DILATATION WAS NOT PERFORMED AND IT WAS CONFIRMED WITH IVUS AND THERE WERE NO REPORTED PROBLEMS. TWO DAYS AFTER THE INDEX PROCEDURE, THE PT EXPERIENCED A MI, ST AND REQUIRED A TVR. THE RCA WAS 100% STENOSED. PCI WAS PERFORMED AND IT WAS DILATED WITH BALLOON. CORONARY ARTERY BYPASS GRAFTING (CABG) WAS PERFORMED. IN THE OPINION OF THE PHYSICIAN, THE RELATIONSHIP OF THE ADVERSE EVENTS TO THE TAXUS STENT ARE POSSIBLY RELATED. THE PT WAS DISCHARGED 50 DAYS LATER. THE STENT WAS WITHDRAWN SURGICALLY AT THE TIME OF THE CABG.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | TAXUS EXPRESS2 PACLITAXEL-ELUTING CORONARY STENT SYSTEM | NIQ STENT, CORONARY, DRUG-ELUTING | NIQ | BOSTON SCIENTIFIC | 2.75X32MM |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 80 YR | Hospitalization| R |