FDA Adverse Event Malfunction Summary report: N

UNK HIP FEMORAL STEM CORAIL

MDR report key: 10943121 · Received December 3, 2020

Report

Report Number
1818910-2020-26118
Event Type
Malfunction
Date Received
December 3, 2020
Date of Event
April 28, 2019
Report Date
November 22, 2020
Manufacturer
DEPUY IRELAND - 9616671
Product Code
KWA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AS
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

PRODUCT COMPLAINT # ==>(B)(4). INVESTIGATION SUMMARY ==> NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. DEPUY CONSIDERS THE INVESTIGATION CLOSED. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED, AND THE INVESTIGATION WILL BE RE-OPENED AS NECESSARY. DEVICE HISTORY LOT ==> THE PRODUCT INVESTIGATION FOUND NO EVIDENCE SUSPECTING AN ERROR IN THE MANUFACTURING OR MATERIAL THAT WOULD BE A CONTRIBUTING FACTOR IN THE REPORTED ALLEGATION(S). WHERE THE LOT CODE WAS PROVIDED, A MANUFACTURING RECORDS EVALUATION (MRE) WAS NOT PERFORMED.

Additional Manufacturer Narrative · 1

(B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

LITERATURE ARTICLE ENTITLED ¿LONG-TERM MIGRATION CHARACTERISTICS OF THE CORAIL HYDROXYAPATITE-COATED FEMORAL STEM: A 14-YEAR RADIOSTEREOMETRIC ANALYSIS FOLLOW-UP STUDY¿ BY OWAIN CRITCHLEY, ET AL, PUBLISHED BY THE ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY (2020), VOL. 140, PP. 121-127, WAS REVIEWED. THE PURPOSE OF THIS STUDY WAS TO MEASURE THE AMOUNT OF SUBSIDENCE FOR A CORAIL CEMENTLESS STEM IMPLANTED IN PATIENTS WITH OSTEOPOROSIS OVER 14 YEARS USING PROGRESSIVE RADIOSTEREOMETRIC IMAGING PERFORMED AT 6 MONTHS, 1 YEAR, 2 YEARS, 6 YEARS, AND 14 YEARS. THE MEASUREMENTS WERE TAKEN USING MARKERS IMPLANTED AT PRIMARY SURGERY. THIS COMPLAINT WILL CAPTURE THE RESULTS FOR 23 PATIENTS IDENTIFIED IN TABLE 1 ON PAGE 124. NO IMPLANTS IN THE STUDY COHORT HAVE BEEN REVISED. ONE RADIOGRAPHIC IMAGE IS AVAILABLE IN FIG 2 ON PAGE 123. RESULTS: PATIENT 15: TOTAL OF 0.316 MM SUBSIDENCE IDENTIFIED ON PROGRESSIVE IMAGING STUDIES OVER 6 YRS. NO PATIENT CONSEQUENCES OR REVISIONS. THE PATIENT DIED AFTER 6-YEAR FOLLOW-UP FOR CAUSES UNRELATED TO THE THA OR THE SURGICAL PROCEDURE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1408054 UNK HIP FEMORAL STEM CORAIL FEMORAL STEM KWA DEPUY IRELAND - 9616671

Patients

Seq Age Sex Outcome Treatment
1