FDA Adverse Event Malfunction Summary report: N

NAVIO SURGICAL SYSTEM AU

MDR report key: 10934586 · Received December 2, 2020

Report

Report Number
3010266064-2020-02058
Event Type
Malfunction
Date Received
December 2, 2020
Date of Event
November 11, 2020
Report Date
March 11, 2022
Manufacturer
BLUE BELT TECHNOLOGIES
Product Code
OLO
PMA / PMN Number
K191223
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
AS
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

H3, H6: THE NAVIO SURGICAL SYSTEM UPS (AUSTRALIA) P/N 200616, S/N (B)(6) INTENDED FOR USE IN TREATMENT WAS RETURNED FOR EVALUATION. A RELATIONSHIP BETWEEN THE REPORTED EVENT AND THE DEVICE WAS ESTABLISHED. NOTHING WAS IDENTIFIED VISUALLY THAT CONTRIBUTED TO THE REPORTED PROBLEM. A FUNCTIONAL EVALUATION WAS PERFORMED. THE UPS WAS CHARGED FOR 24 HOURS THEN INSERTED INTO A NAVIO SYSTEM. THE REPORTED PROBLEM WAS CONFIRMED. THE UPS BATTERIES INDICATE THAT THEY ARE NOT CHARGED. THE SYSTEM BOOTS TO A 2X12 ZEROS ERROR ALSO CONFIRMING THE UPS FAILURE. A REVIEW OF MANUFACTURING AND SERVICE RECORDS INDICATE THE DEVICE MET ALL SPECIFICATIONS UPON RELEASE INTO DISTRIBUTION. A COMPLAINT HISTORY REVIEW FOR SIMILAR REPORTED/CONFIRMED COMPLAINTS HAS IDENTIFIED PRIOR EVENTS. THE MOST LIKELY CAUSE OF THIS EVENT IS A FAILURE OF THE CHARGING CIRCUIT IN THE UPS. THE UPS IS AN OEM PART AND CANNOT BE FURTHER DISASSEMBLED TO ARRIVE AT A ROOT CAUSE. A HISTORICAL ESCALATION EVENT REVIEW WAS COMPLETED. A REVIEW OF PRIOR ESCALATION ACTIONS FOUND NO ACTIONS APPLICABLE TO THE SCOPE OF THE REPORTED COMPLAINT. THIS FAILURE MODE AND ASSOCIATED RISK HAVE BEEN ANTICIPATED WITHIN THE RISK FILE AND THE DOCUMENTED RISK LEVEL IS STILL ADEQUATE. ALTHOUGH NO FURTHER CONTAINMENT OR CORRECTIVE ACTION IS RECOMMENDED OR REQUIRED AT THIS TIME, ALL COMPLAINTS ARE MONITORED AND TRENDED THROUGH POST MARKET SURVEILLANCE ACTIVITIES.

Description of Event or Problem · 1

IT WAS REPORTED THAT, DURING A NAVIO PREVENTIVE MAINTENANCE, THERE WAS AN UPS COMMUNICATION ERROR WITH A BRAND NEW SET OF BATTERIES. THE CHARGING CIRCUIT MAY BE FAULTY. THEY TRIED THE RECOMMENDED TROUBLESHOOTING TO NO AVAIL (WITH THE NAVIO COMPLETELY POWERED OFF, THEY UNPLUGGED THE POWER CORD AND TURN ON THE UNIT. ONCE THEY SAW THE NAVIO SPLASH SCREEN, THEY RECONNECTED THE POWER CORD. THE RED LIGHT SHOULD GO OFF AND THE NAVIO SHOULD BOOT NORMALLY. IF IT BOOTS UP NORMALLY, POWER IT BACK DOWN AND LET IT CHARGE A FEW MINUTES AND POWER BACK UP. IF THE RED LIGHT COMES BACK, THEN THERE IS LIKELY A BATTERY OR UPS PROBLEM). THEY REPLACED THE UPS AND THE SYSTEM RETURNED TO FULL FUNCTIONALITY. NO PATIENT WAS INVOLVED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1400996 NAVIO SURGICAL SYSTEM AU ORTHOPEDIC STEREOTAXIC INSTRUMENT OLO BLUE BELT TECHNOLOGIES

Patients

Seq Age Sex Outcome Treatment
1 Unknown ISOLATION TRANSFORMER/UPS, U.S.| ISOLATION TRANSFORMER/UPS, U.S.