FDA Adverse Event Malfunction Summary report: N

ORTHOPEDIC SALVAGE SYSTEM MODULAR PROXIMAL TIBIAL BODY 9CM

MDR report key: 10905786 · Received November 25, 2020

Report

Report Number
0001825034-2020-04218
Event Type
Malfunction
Date Received
November 25, 2020
Date of Event
November 2, 2020
Report Date
April 26, 2021
Manufacturer
ZIMMER BIOMET, INC.
Product Code
KRO
PMA / PMN Number
K051479
Removal / Correction Number
N/A
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. CONCOMITANT MEDICAL PRODUCT- ORTHOPEDIC SALVAGE SYSTEM 7CM DIAPHYSEAL SEGMENT CATALOG #: 150466 LOT #: 013430, ORTHOPEDIC SALVAGE SYSTEM 3CM DIAPHYSEAL SEGMENT CATALOG #: 150464 LOT #: 517270. MULTIPLE MDR REPORTS WERE FILED FOR THIS PATIENT; PLEASE SEE ALL REPORTS ASSOCIATED WITH THIS EVENT: 0001825034-2020-04217, 0001825034-2020-04387.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS BEING SUBMITTED TO RELAY ADDITIONAL INFORMATION. THE PRODUCT WAS EVALUATED THROUGH MANUFACTURING REVIEW, HOWEVER, THE REPORTED EVENT COULD NOT BE CONFIRMED. PHOTOGRAPHS WERE PROVIDED, WHICH SHOWED THE INTRAOPERATIVE SITE WITH THE TIBIAL BODY CONNECTED TO THE DIAPHYSEAL SEGMENT. THE DEVICE HISTORY RECORDS WERE REVIEWED AND NO DISCREPANCIES WERE IDENTIFIED. A DEFINITIVE ROOT CAUSE COULD NOT BE DETERMINED WITH THE INFORMATION PROVIDED. IF ANY FURTHER INFORMATION IS FOUND WHICH WOULD CHANGE OR ALTER ANY CONCLUSIONS OR INFORMATION, A SUPPLEMENTAL WILL BE FILED ACCORDINGLY. ZIMMER BIOMET WILL CONTINUE TO MONITOR FOR TRENDS.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

Description of Event or Problem · 0

NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

Additional Manufacturer Narrative · 1

(B)(4). CONCOMITANT MEDICAL PRODUCTS: ORTHOPEDIC SALVAGE SYSTEM 7CM DIAPHYSEAL SEGMENT CATALOG #: 150466 LOT #: NI, ORTHOPEDIC SALVAGE SYSTEM FEMORAL DIAPHYSEAL COUPLER 30CM CATALOG #: 150463 LOT #: NI REPORT SOURCE: (B)(6). THE COMPLAINANT HAS INDICATED THAT THE PRODUCT WILL NOT BE RETURNED TO ZIMMER BIOMET FOR INVESTIGATION. THE INVESTIGATION IS IN PROCESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED. MULTIPLE MDR REPORTS WERE FILED FOR THIS PATIENT; PLEASE SEE ALL REPORTS ASSOCIATED WITH THIS EVENT: 0001825034-2020-04217.

Description of Event or Problem · 1

IT IS REPORTED THAT DURING A KNEE ARTHROPLASTY REVISION TO ADDRESS UNRELATED REASONS, THE SURGEON ATTEMPTED TO ADJUST THE TIBIAL LENGTH. HOWEVER, AFTER REMOVING THE SCREWS BETWEEN THE TIBIAL BODY AND DIAPHYSEAL SEGMENT, THE SURGEON WAS UNABLE TO DISENGAGE THE IMPLANT TAPER LOCK. THE SURGERY WAS COMPLETED WITHOUT EXTENDING THE TIBIAL LENGTH AND IT IS UNKNOWN WHETHER AN ADDITIONAL SURGERY HAS BEEN PLANNED, HOWEVER, THE SURGEON HAS REQUESTED FURTHER INSTRUCTIONS IN ORDER TO LENGTHEN THE TIBIA AT A LATER DATE. ATTEMPTS HAVE BEEN MADE, HOWEVER, NO ADDITIONAL INFORMATION IS AVAILABLE AT THIS TIME.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1367762 ORTHOPEDIC SALVAGE SYSTEM MODULAR PROXIMAL TIBIAL BODY 9CM PROSTHESIS, KNEE KRO ZIMMER BIOMET, INC. N/A 510700

Patients

Seq Age Sex Outcome Treatment
1