FDA Adverse Event Injury Summary report: N

SAPIEN VALVE UNKNOWN

MDR report key: 10839586 · Received November 13, 2020

Report

Report Number
2015691-2020-14386
Event Type
Injury
Date Received
November 13, 2020
Date of Event
April 26, 2020
Report Date
October 19, 2020
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
FR
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

THIS IS ONE OF FOUR REPORTS SUBMITTED FOR THIS ARTICLE. REFERENCE RELATED MANUFACTURER REPORT NUMBER: 2015691-2020-14384, 2015691-2020-14385, 2015691-2020-14386, 2015691-2020-14388.

Additional Manufacturer Narrative · 1

THE DATE OF THE EVENTS ARE UNKNOWN. THEREFORE, THE DATE OF THE MANUSCRIPT WAS RECEIVED, APRIL 26, 2020, WAS USED AS THE OCCURRENCE DATE. THE MODELS OF SAPIEN VALVES USED WERE NOT PROVIDED. THE PMA NUMBERS ARE P110021 FOR SAPIEN, P130009 FOR SAPIEN XT, AND P140031 FOR SAPIEN 3. ARTICLE REFERENCE: ZOUARI, FOURAT, FRANCISCO CAMPELO-PARADA, ANTHONY MATTA, NICOLAS BOUDOU, FRÉDÉRIC BOUISSET, ETIENNE GRUNENWALD, BERTRAND MARCHEIX, DIDIER CARRIÉ, AND THIBAULT LHERMUSIER. "CONDUCTION DISTURBANCES IN LOW-SURGICAL-RISK PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT WITH SELF-EXPANDABLE OR BALLOON-EXPANDABLE VALVES." CARDIOVASCULAR INTERVENTION AND THERAPEUTICS (2020): 1-8. ACCORDING TO THE INSTRUCTIONS FOR USE (IFU), CARDIOVASCULAR COMPLICATIONS, INCLUDING PERFORATION OR DISSECTION OF VESSELS WHICH MAY REQUIRE INTERVENTION, ARE POTENTIAL ADVERSE EVENTS ASSOCIATED WITH THE TRANSFEMORAL TRANSCATHETER AORTIC VALVE REPLACEMENT PROCEDURE. ACCORDING TO LITERATURE REVIEW, AND AS DOCUMENTED IN A TECHNICAL SUMMARY WRITTEN BY EDWARDS LIFESCIENCES, VASCULAR COMPLICATIONS ARE A WELL-RECOGNIZED COMPLICATION OF THE TRANSFEMORAL TAVR PROCEDURE IN THIS ELDERLY POPULATION WITH MULTIPLE CO-MORBIDITIES. EDWARDS HAS REVIEWED MANY REPORTS, INCLUDING SCREENING DATA RECORDS AND SOURCE DOCUMENTATION OF VASCULAR COMPLICATIONS AND HAS FOUND THAT THE ROOT CAUSE IS TYPICALLY RELATED TO A COMBINATION OF VESSEL SIZE, TORTUOSITY AND CALCIFICATIONS. ALTHOUGH THE INCIDENCE IS DECREASING WITH SMALLER SHEATH/DELIVERY SYSTEM SIZES AND PHYSICIAN EXPERIENCE, THERE WILL CONTINUE TO BE CASES IN WHICH VASCULAR COMPLICATIONS WILL OCCUR. THE THV PHYSICIAN TRAINING MANUALS INSTRUCT ON PROCEDURAL CONSIDERATIONS FOR SHEATH INSERTION WITH REGARDS TO PROPER SCREENING CRITICAL TO REDUCING VASCULAR COMPLICATIONS. THE TRAINING MANUAL INSTRUCTS THE OPERATOR ON PROPER SHEATH INSERTION AND WITHDRAWAL TECHNIQUES, INCLUDING PRE-DILATING THE VESSEL WITH THE EDWARDS DILATORS, AS NEEDED. IT ALSO NOTES THAT CALCIFICATION MAY REDUCE LUMEN DIAMETER AND LIMIT OR PREVENT TRANSFEMORAL PASSAGE OF THE DEVICES. THE IFU CONTRAINDICATES PATIENTS WITH ILIO-FEMORAL VESSEL CHARACTERISTICS THAT WOULD PRECLUDE SAFE PLACEMENT OF SHEATHS SUCH AS SEVERE OBSTRUCTIVE CALCIFICATION OR SEVERE TORTUOSITY. PRE-PROCEDURE SCREENING AND ASSESSMENT OF THE FEMORAL/ILIAC ARTERY INTERNAL DIAMETERS WILL ENABLE THE CLINICIAN TO DETERMINE IF THE SAPIEN VALVE CAN BE DELIVERED TRANSFEMORALLY. ASSESSMENT OF LOCATION AND AMOUNT OF CIRCUMFERENTIAL CALCIUM WILL AID IN DETERMINING AREAS OF REDUCED VESSEL DIAMETERS. THE OPERATORS ARE TRAINED TO MEASURE MINIMUM VESSEL DIAMETER TAKING CALCIUM INTO ACCOUNT. THE PHYSICIAN TRAINING MANUAL ALSO LISTS THE MINIMUM RECOMMENDED VESSEL SIZE FOR EACH SIZE DEVICE. DESPITE THE BEST SCREENING TOOLS, A SMALL PERCENTAGE OF PATIENTS WILL HAVE FEMORAL/ILIAC VESSELS THAT ARE NOT AMENABLE TO THE TRANS-FEMORAL APPROACH OR WHERE INCREASED RESISTANCE IS ENCOUNTERED DURING INSERTION OF DEVICES. IN MANY CASES, THE VESSEL MINIMUM LUMINAL DIAMETER (MLD) MAY BE BORDERLINE OR BELOW THE INDICATED SIZE. IN ADDITION, SIGNIFICANT CALCIFICATION AND/OR TORTUOSITY, NOT ALWAYS APPRECIABLE ON IMAGING, COULD BE CONTRIBUTING FACTORS TO THE EVENT. IN THIS CASE, THERE WAS NO ALLEGATION OR INDICATION A DEVICE MALFUNCTION CONTRIBUTED TO THIS ADVERSE EVENT. THE CAUSE FOR THE MAJOR VASCULAR COMPLICATIONS COULD NOT BE DETERMINED WITH THE INFORMATION PROVIDED BY THE AUTHORS. HOWEVER, PATIENT FACTORS AND/OR THE MECHANISMS DESCRIBED ABOVE ARE LIKELY CONTRIBUTING FACTORS FOR THE EVENTS. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED AT THIS TIME.

Description of Event or Problem · 1

AS REPORTED BY OUR AFFILIATES IN (B)(6), PER THE MEDICAL ARTICLE, ¿CONDUCTION DISTURBANCES IN LOW-SURGICAL-RISK PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT WITH SELF-EXPANDABLE OR BALLOON-EXPANDABLE VALVES¿, 116 LOW-RISK PATIENTS WITHOUT PRE-EXISTING CONDUCTION DISTURBANCES UNDERWENT TAVR WITH EITHER BALLOON-EXPANDABLE EDWARDS VALVES OR SELF-EXPANDABLE NON-EDWARDS VALVES. ALL PATIENTS PRESENTED WITH SYMPTOMATIC, SEVERE AORTIC STENOSIS. DURING THE STUDY PERIOD, 3 PATIENTS HAD MAJOR VASCULAR COMPLICATIONS.