Additional Manufacturer Narrative · 1

MULTIPLE PATIENT INVOLVED. IMPLANTATION DATE UNKNOWN 510 K: THIS REPORT IS FOR AN UNKNOWN CAGE/SPACER/UNKNOWN LOT. PART AND LOT NUMBERS ARE UNKNOWN; UDI NUMBER IS UNKNOWN. COMPLAINANT PART IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. WITHOUT A LOT NUMBER, THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED AS NO PRODUCT WAS RECEIVED. THE INVESTIGATION COULD NOT BE COMPLETED, NO PRODUCT WAS RECEIVED; NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. (B)(4). DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: JURICEK M., REHAK L., REHAK J., TISOVSKY P.,(2010)QUALITY OF LIFE AFTER ELECTIVE LUMBAR SPINAL FUSIONS, BRATISL LEK LISTY VOLUME 111(5) , PAGES 290-295 (SLOVAKIA). THIS STUDY AIMS TO EVALUATE THE QUALITY OF LIFE AFTER ELECTIVE LUMBAR SPINAL FUSIONS. FROM 2005 TO JUNE 2007 , A TOTAL OF 208 PATIENTS (120 FEMALES, 88 MALES) WITH MEAN AGE OF 54.6-9.04 YEARS (RANGE 32-69 YEARS) THAT UNDERWENT AN ELECTIVE STABILIZATION WITH DECOMPRESSION AND FUSION FOR DEGENERATIVE LUMBAR SPINE WERE INCLUDED IN THE STUDY. PATIENTS WERE TREATED USING THE EXPEDIUM SYSTEM. THE TRANSFORAMINAL LUMBAR INTERBODY FUSION (TLIF) WITH CAGES LEOPARD AND DEVEX WAS PERFORMED IN 165 PATIENTS, THE ANTERIOR LUMBAR INTERBODY FUSION (ALIF) WITH BRANTIGAN CAGES IN 5 PATIENTS AND THE POSTEROLATERAL LUMBAR FUSION (PLF) IN 38 PATIENTS. PATIENTS WERE EVALUATED AT 6, 12 AND 24 MONTHS AFTER SURGERY. THE FOLLOWING COMPLICATIONS WERE REPORTED AS FOLLOWS: AFTER SURGERY 74 OF PATIENTS USED ANALGESICS SOMETIMES AND 68 PATIENTS USED THEM DAILY. A REVISION SURGERY WAS NECESSARY IN 18 CASES. 5 CASES OF DURAL SACK LESIONS WERE A FEW MM2 AND WERE SOLVED WITH A SIMPLE SUTURE , WITHOUT A NEED OF FURTHER REVISION. 2 DEEP INFECTION DEVELOPED, THEY WERE MANAGED BY AN EARLY REVISION, DRAINAGE, AND ANTIBIOTIC THERAPY. 4 SUPERFICIAL INFECTION RESOLVED WITH ANTIBIOTIC THERAPY. 2 CASES OF DONOR SITE PAIN. 1 CASE OF BREAKAGE OF CARBON CAGE OCCURRED DURING OPERATION-THE COMPLICATION WAS RESOLVED BY AN IMMEDIATE EXTRACTION AND EXCHANGE FOR A TITANIUM CAGE. 1 CASE OF IMPROPER INTRODUCTION OF TLIF CAGE WAS REVISED, EXTRACTED BY ANTERIOR APPROACH, AND CONVERSED TO ALIF. MOST FREQUENT COMPLICATIONS WERE RELATED TO INSTRUMENTATION-17 : IMPROPER INTRODUCTION OF SCREWS IN 8 PATIENTS WAS DEALT WITH A REVISION: IN 3 PATIENTS, A PERMANENT NEUROLOGICAL COMPLICATION OCCURRED- IN ALL CASES IT WAS UNILATERAL PARESIS OF LOWER LIMBS, NO PATIENT HAD SPHINCTER OR SEXUAL DISORDER. 7 BROKEN SCREWS WERE EXTRACTED AND REPLACED. THIS REPORT IS FOR AN UNKNOWN DEPUY SPINE EXPEDIUM SYSTEM, UNKNOWN DEPUY SPINE LEOPARD, UNKNOWN DEPUY SPINE DEVEX AND UNKNOWN DEPUY SPINE BRANTIGAN CAGE. THIS REPORT IS FOR (1) UNKNOWN CAGE/SPACER. THIS IS REPORT 6 OF 10 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1299433 UNKNOWN CAGE/SPACER INTERVERTEBRAL FUSION DEVICE W/INTEGRATED FIXATION, LUMBAR OVD MEDOS INTERNATIONAL SàRL CH

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention