FDA Adverse Event Malfunction Summary report: N

SYRINGE 3ML SALINE 3ML FILL

MDR report key: 10795789 · Received November 5, 2020

Report

Report Number
1911916-2020-01010
Event Type
Malfunction
Date Received
November 5, 2020
Date of Event
October 14, 2020
Report Date
November 6, 2020
Manufacturer
BD MEDICAL (BD WEST) MEDICAL SURGICAL
Product Code
NGT
UDI-DI
30382903065449
PMA / PMN Number
K003553
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IL, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES, D10: RETURNED TO MANUFACTURER ON: 2020-10-22. H6: INVESTIGATION SUMMARY: A DEVICE HISTORY RECORD REVIEW WAS PERFORMED FOR PROVIDED LOT NUMBER 43481. THE REVIEW DID NOT REVEAL ANY DETECTED QUALITY ISSUES DURING THE PRODUCTION PROCESS THAT COULD HAVE CONTRIBUTED TO THIS REPORTED INCIDENT. TO AID IN THE INVESTIGATION OF THIS INCIDENT, THREE SAMPLES WERE RECEIVED BY OUR QUALITY INSPECTION TEAM FOR EVALUATION. THE SAMPLES WERE VISUALLY INSPECTED FINDING NO DEFECTS OF ANY KIND. EACH WAS TESTED FOR SUSTAINING FORCE AND WERE WITHIN SPECIFICATION. AS THE RESULTS OF THE INVESTIGATION WERE WITHIN SPECIFICATION AND NO DEFECTS WERE FOUND, A CAUSE FOR THE REPORTED INCIDENT COULD NOT BE DETERMINED. FURTHER ACTION HAS NOT BEEN DETERMINED NECESSARY AT THIS TIME. OUR QUALITY TEAM WILL CONTINUE TO MONITOR THE MANUFACTURING PROCESS FOR THIS DEFECT AND OTHER EMERGING TRENDS.

Description of Event or Problem · 0

IT WAS REPORTED THAT 3 SYRINGE 3ML SALINE 3ML FILL EXPERIENCED LEAKAGE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO: 306544 BATCH NO: 0210090, 0043481. I AM INQUIRING ABOUT THE USE OF THE 3ML POSIFLUSH WITH A 24 GAUGE INSTYE AUTOGUARD W/O BLOOD CONTROL IV CATHETER. HOSPITAL RECENTLY SWITCHED FROM A STANDARD 3ML SYRINGE TO THE POSIFLUSH 3ML STUBBY DESIGN AND IS EXPERIENCING MORE BLOWN IV SITES THAN USUAL. THEY'VE PINPOINTED THE USE OF THE STUBBY FLUSH AS THE STEP IN THE PROCESS WHERE THEY ARE BLOWING THE LINE, FEARING IT IS THE GREATER FORCE AND PRESSURE BEHIND THE PLUNGER ROD. I DID EXPLAIN THAT THE BY DESIGN, THE STUBBY FLUSH ACTUALLY HAS SIGNIFICANTLY LESS PSI FORCE AND REFLUX COMPARED TO THE STANDARD DESIGN, AND REVIEWED THEIR FLUSHING TECHNIQUE, RECOMMENDING A PUSH PAUSE METHOD. THE MEDICAL SUPPORT TEAM SUGGESTED I SUBMIT THIS IS AS A COMPLAINT, SHOULD THERE BE SOMETHING DEFECTIVE ABOUT THE IV OR FLUSH.

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED. THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 0210090, MEDICAL DEVICE EXPIRATION DATE: 2023-06-30, DEVICE MANUFACTURE DATE: 2020-07-28, MEDICAL DEVICE LOT #: 0043481, MEDICAL DEVICE EXPIRATION DATE: 2023-01-31, DEVICE MANUFACTURE DATE: 2020-02-12. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED THAT 3 SYRINGE 3ML SALINE 3ML FILL EXPERIENCED LEAKAGE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO: 306544 BATCH NO: 0210090, 0043481. I AM INQUIRING ABOUT THE USE OF THE 3ML POSIFLUSH WITH A 24 GAUGE INSTYE AUTOGUARD W/O BLOOD CONTROL IV CATHETER. HOSPITAL RECENTLY SWITCHED FROM A STANDARD 3ML SYRINGE TO THE POSIFLUSH 3ML STUBBY DESIGN AND IS EXPERIENCING MORE BLOWN IV SITES THAN USUAL. THEY'VE PINPOINTED THE USE OF THE STUBBY FLUSH AS THE STEP IN THE PROCESS WHERE THEY ARE BLOWING THE LINE, FEARING IT IS THE GREATER FORCE AND PRESSURE BEHIND THE PLUNGER ROD. I DID EXPLAIN THAT THE BY DESIGN, THE STUBBY FLUSH ACTUALLY HAS SIGNIFICANTLY LESS PSI FORCE AND REFLUX COMPARED TO THE STANDARD DESIGN, AND REVIEWED THEIR FLUSHING TECHNIQUE, RECOMMENDING A PUSH PAUSE METHOD. THE MEDICAL SUPPORT TEAM SUGGESTED I SUBMIT THIS IS AS A COMPLAINT, SHOULD THERE BE SOMETHING DEFECTIVE ABOUT THE IV OR FLUSH.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1254984 SYRINGE 3ML SALINE 3ML FILL SALINE, VASCULAR ACCESS FLUSH NGT BD MEDICAL (BD WEST) MEDICAL SURGICAL 306544 SEE H10 30382903065449

Patients

Seq Age Sex Outcome Treatment
1