FDA Adverse Event Injury Summary report: N

LIGASURE

MDR report key: 10789314 · Received November 4, 2020

Report

Report Number
1717344-2020-01359
Event Type
Injury
Date Received
November 4, 2020
Date of Event
August 13, 2020
Report Date
November 4, 2020
Manufacturer
COVIDIEN MFG DC BOULDER
Product Code
GEI
UDI-DI
10884521186033
PMA / PMN Number
K152286
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NL
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

TITLE: REDUCED MORBIDITY BY USING LIGASURE COMPARED TO CONVENTIONAL INGUINOFEMORAL LYMPHADENECTOMY IN VULVAR CANCER PATIENTS: A RANDOMIZED CONTROLLED TRIAL. SOURCE: SURGICAL ONCOLOGY VOLUME 35, DECEMBER 2020, PAGES 149-15 . IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

ACCORDING TO THE LITERATURE STUDY, BETWEEN OCTOBER 2017 AND OCTOBER 2018, 20 PATIENTS WITH 40 GROINS REQUIRING BILATERAL INGUINOFEMORAL LYMPHADENECTOMY (IFL) WERE INCLUDED IN THIS STUDY. TEN PATIENTS WERE ALLOCATED TO IFL WITH LIGASURE IN THE RIGHT GROIN AND TEN PATIENTS WERE ALLOCATED TO LIGASURE IN THE LEFT GROIN. POSTOPERATIVE SHORT-TERM COMPLICATIONS REQUIRING TREATMENT OCCURRED IN 6/20 GROINS TREATED WITH LIGASURE: 1 WOUND INFECTION; 4 WOUND INFECTION AND LYMPHOCELE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1253971 LIGASURE ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES GEI COVIDIEN MFG DC BOULDER LF1212A 10884521186033

Patients

Seq Age Sex Outcome Treatment
1 Other