FDA Adverse Event Injury Summary report: N

NC TREK CORONARY DILATATION CATHETER

MDR report key: 10759282 · Received October 29, 2020

Report

Report Number
2024168-2020-09051
Event Type
Injury
Date Received
October 29, 2020
Date of Event
September 11, 2020
Report Date
November 19, 2020
Manufacturer
ABBOTT VASCULAR
Product Code
LOX
UDI-DI
08717648151996
PMA / PMN Number
K103153
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
KY, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

THERE WAS NO REPORTED DEVICE MALFUNCTION AND THE PRODUCT WAS NOT RETURNED. A REVIEW OF THE LOT HISTORY RECORD COULD NOT BE CONDUCTED BECAUSE THE LOT NUMBER WAS NOT PROVIDED. THE REPORTED PATIENT EFFECT OF PERFORATION IS LISTED IN THE CORONARY DILATATION CATHETERS (CDC), NC TREK RX, GLOBAL, INSTRUCTION FOR USE (IFU) AS KNOWN PATIENT EFFECT. A CONCLUSIVE CAUSE FOR THE REPORTED PATIENT EFFECT AND THE RELATIONSHIP TO THE PRODUCT, IF ANY, CANNOT BE DETERMINED. ADDITIONALLY, SURGICAL PROCEDURE, ADDITIONAL TREATMENT AND HOSPITALIZATION APPEAR TO BE RELATED TO OPERATIONAL CONTEXT OF THE PROCEDURE. THERE IS NO INDICATION OF A PRODUCT QUALITY ISSUE WITH RESPECT TO THE DESIGN, MANUFACTURE, OR LABELING OF THE DEVICE.

Additional Manufacturer Narrative · 1

THE CUSTOMER REPORTED THE DEVICE IS NOT RETURNING. INVESTIGATION IS NOT YET COMPLETE. A FOLLOW-UP REPORT WILL BE SUBMITTED WITH ALL ADDITIONAL RELEVANT INFORMATION. THE OTHER DEVICES MENTIONED ARE FILED UNDER SEPARATE MEDWATCH REPORT NUMBERS.

Description of Event or Problem · 1

IT WAS REPORTED THAT DURING A RIGHT CORONARY ARTERY STENTING PROCEDURE, A 3.0 X 15 MM XIENCE SIERRA DRUG-ELUTING STENT WAS DEPLOYED ACROSS THE DISTAL STENOSIS AT 16 ATMOSPHERES. AT THAT TIME, THERE WAS A DISRUPTION OF THE PROXIMAL TO MID RIGHT CORONARY ARTERY STENOSIS AND THE DECISION WAS MADE TO COVER THIS AREA WITH A DRUG-ELUTING STENT. A 3.5 X 28 MM XIENCE SIERRA WAS THEN SUCCESSFULLY IMPLANTED AND POST-DILATED WITH A 3.5X20MM NC TREK. AFTER POST-DILATATION, A PERFORATION WAS NOTED. AT THAT TIME, A 3.5 X16 MM GRAFTMASTER COVERED STENT (9072241) WAS IMPLANTED ACROSS THE PERFORATION AT 20 ATMOSPHERES (ABOVE RATED BURSE PRESSURE), RESOLVING THE PERFORATION; HOWEVER, THE STENT WAS POST-DILATED WITH THE 3.5X20MM NC TREK AND THE PERFORATION WAS NOTED TO CONTINUE TO LEAK. TWO ADDITIONAL 3.5X19 GRAFTMASTER STENTS (9112841, 9032941) WERE IMPLANTED, ONE PROXIMAL AND ONE DISTAL TO THE IMPLANTED 3.5X16MM GRAFTMASTER STENT, BUT THE PERFORATION CONTINUED TO LEAK. AN ADDITIONAL XIENCE SIERRA 3.5 X 38 MM STENT WAS IMPLANTED BUT THE PERFORATION CONTINUED TO LEAK. A 2.8X19MM GRAFTMASTER STENT (8120641) WAS ADVANCED, BUT FAILED TO GET DISTAL TO THE LAST GRAFTMASTER STENT AND THE XIENCE SIERRA. ANOTHER 2.8X19MM GRAFTMASTER STENT (9092641) KINKED UPON INSERTION INTO THE PATIENT. A 3.5X19 GRAFTMASTER STENT (9060541) WAS ADVANCED, BUT FAILED TO CROSS THE IMPLANTED XIENCE SIERRA STENT. ANOTHER 2.8X19MM GRAFTMASTER STENT (8120641) WAS ADVANCED BUT FAILED TO GET DISTAL TO THE LAST GRAFTMASTER STENT AND THE XIENCE SIERRA. THE PATIENT WAS TAKEN TO SURGERY WHERE THE PERFORATION WAS TREATED SUCCESSFULLY. THERE WAS NO REPORTED ADVERSE PATIENT SEQUELA. THERE WAS NO ADDITIONAL INFORMATION PROVIDED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1219837 NC TREK CORONARY DILATATION CATHETER CORONARY DILATATION CATHETER LOX ABBOTT VASCULAR 1012451-20 08717648151996

Patients

Seq Age Sex Outcome Treatment
1 68 YR Hospitalization| R XIENCE XPEDITION 3.5X28MM