GEENEN PANCREATIC STENT
Report
- Report Number
- 3005580113-2020-00435
- Event Type
- Injury
- Date Received
- October 26, 2020
- Date of Event
- November 20, 2004
- Report Date
- October 26, 2020
- Manufacturer
- COOK IRELAND LTD
- Product Code
- FGE
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Distributor report
- Reporter Location
- AL, US
- Reporter Occupation
- OTHER
Narratives
PROCODE: FGE CATHETER, BILIARY, DIAGNOSTIC.
"VARADARAJULU ET AL 2005 (GEENEN PS) ¿ ¿PREDICTORS OF OUTCOME IN PANCREATIC DUCT DISRUPTION MANAGED BY ENDOSCOPIC TRANSPAPILLARY STENT PLACEMENT¿. ERCP WAS PERFORMED WITH THE PATIENT UNDER STANDARD CONSCIOUS SEDATION. UPON IDENTIFICATION OF THE PD DISRUPTION AS EXTRAVASATION OF CONTRAST INTO THE PFC, A 0.035-INCH GUIDEWIRE WAS INSERTED INTO THE PD AND A GEENEN PANCREATIC STENT (WILSON-COOK MEDICAL INC, (B)(4)) WITH AN INTERNAL FLAP WAS INSERTED. WHEN A 3F STENT WAS PLACED, A SMALL CUT WAS MADE ON THE STENT TO CREATE AN INTERNAL FLAP. THE PD WAS CANNULATED WITH A 0.018-INCH GUIDEWIRE WHEN THERE WAS AN EXTREMELY NARROW PD STRICTURE OR WHEN A 3F STENT WAS PLACED. PANCREATOGRAPHY WAS OBTAINED IN ALL PATIENTS AT STENT REMOVAL, WHICH USUALLY WAS DONE 6 TO 8 WEEKS AFTER PLACEMENT. FOR A PERSISTENT LEAK, A NEW STENT WAS PLACED AND WAS EXCHANGED AT INTERVALS OF 6 TO 8 WEEKS. THE DIAMETERS OF THE PD STENTS USED WERE THE FOLLOWING: 3F (15%), 5F (45%), 7F (38%), AND 10F (2%). OFF LABEL USE: TO TREAT FISTULA. ALTERING THE 3 FR STENT (CUT TO ADD INTERNAL FLAP). STENT OCCLUSION (5 PATIENTS): IN 5 PATIENTS, THE STENT WAS OCCLUDED AT REMOVAL. IN TWO, THERE WAS RESOLUTION OF THE DUCT DISRUPTION, BUT PERSISTENT DISRUPTION IN THE OTHER 3 NECESSITATED SURGERY. IN 3 PATIENTS, THE PANCREATIC STENT WAS OCCLUDED AT REMOVAL 8 WEEKS LATER. IN ONE PATIENT WITH AN OCCLUDED STENT, THE DUCT LEAK (BODY OF PANCREAS) WAS STILL PRESENT AND A NEW LEAK HAD DEVELOPED IN THE REGION OF THE TAIL; DISTAL PANCREATECTOMY WAS PERFORMED, AND THE PATIENT WAS DOING WELL AT 6 MONTHS¿ FOLLOW-UP. IN TWO OTHER PATIENTS WITH OCCLUDED STENTS, THE DUCT LEAK AT THE GENU HAD RESOLVED; BOTH WERE WELL AT THE 18 MONTHS¿ FOLLOW-UP. IN TWO PATIENTS, PUS WAS SEEN TO FLOW FROM THE PD ORIFICE AT STENT REMOVAL. BOTH HAD OCCLUDED STENTS (5F AND 7F, RESPECTIVELY); IN ONE, A PANCREATICOCUTANEOUS FISTULA WAS STILL PRESENT, AND, IN THE OTHER, THE DUCTAL LEAK IN THE BODY HAD WORSENED. BOTH PATIENTS UNDERWENT PANCREATIC DEBRIDEMENT. AT 3 MONTHS AFTER SURGERY, ONE PATIENT WAS DOING WELL AND THE OTHER HAD A PERCUTANEOUS DRAIN THAT WAS PLACED UNDER RADIOLOGIC GUIDANCE FOR A RECURRENT PFC.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1199387 | GEENEN PANCREATIC STENT | FGE | COOK IRELAND LTD | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 54 YR | Required Intervention |