FDA Adverse Event Malfunction Summary report: N

SYRINGE 0.3ML 31GA 8MM 10BAG 500 WAL

MDR report key: 10709408 · Received October 21, 2020

Report

Report Number
1920898-2020-01438
Event Type
Malfunction
Date Received
October 21, 2020
Date of Event
September 28, 2020
Report Date
November 20, 2020
Manufacturer
BD MEDICAL - DIABETES CARE
Product Code
FMF
UDI-DI
00681131311786
PMA / PMN Number
K024112
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MD, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: H.6. METHOD CODES: 10. RESULT CODES: 170. CONCLUSION CODES: 4315. H.6. INVESTIGATION SUMMARY: A VISUAL EVALUATION OF PHOTO FOUND (4) SYRINGES WITH NO NEEDLE ASSEMBLY ATTACHED. THERE DID NOT APPEAR TO BE ANY DAMAGE TO THE TIP OF THE BARRELS, OR ANYWHERE ON THE SYRINGE. THERE DID NOT APPEAR TO BE ANY CORE PIN DAMAGE. DHR, L2L DISPATCHES, AND LOGBOOK ENTRIES WERE LOOKED AT, NOTHING PERTAINING TO THIS DEFECT WAS FOUND. ROOT CAUSE FOR THIS DEFECT CANNOT BE DETERMINED. CAPA1630423 HAS BEEN OPENED TO ADDRESS THIS ISSUE. CUSTOMER RETURNED (4) 3/10CC, 8MM, 31G RELION SYRINGES IN AN OPEN POLY BAG FROM LOT # 9231336. CUSTOMER STATES THAT THE NEEDLE HUB SEPARATED. ALL RETURNED SYRINGES WERE EXAMINED AND ALL EXHIBITED THE HUB-NEEDLE/SHIELD ASSEMBLY SEPARATED FROM THE BARREL. MANUFACTURING (HOLDREGE) WILL BE NOTIFIED OF THIS ISSUE. H3 OTHER TEXT : SEE H.10.

Description of Event or Problem · 0

IT WAS REPORTED THAT A SYRINGE 0.3ML 31GA 8MM 10BAG 500 WAL SEPARATED FROM THE HUB DURING USE. THE FOLLOWING WAS REPORTED BY THE INITIAL REPORTER: "IT WAS REPORTED THAT NEEDLE HUB SEPARATED. VERBATIM: CONSUMER REPORTED THAT THE NEEDLE HUB SEPARATED AND STAYED INSIDE OF THE SHIELD. THE SHIELD WAS NOT DIFFICULT TO REMOVE."

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. MEDICAL DEVICE EXPIRATION DATE: UNKNOWN. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED. LEVEL B INVESTIGATION: COMPLAINT EVALUATION / COMPLAINT HISTORY CHECK FOR THE EVENT(S) THAT OCCURRED. SEVERITY: S_1__; OCCURRENCE: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 9TH. RELATED COMPLAINT FOR NEEDLE HUB SEPARATES ON LOT # 9231336. A REVIEW OF RISK MANAGEMENT DOCUMENT (B)(4) INDICATES THAT THE POTENTIAL RISK OF THIS SPECIFIC REPORTED INCIDENT (INSULIN SYRINGE), NEEDLE HUB SEPARATES) WAS CAPTURED AND ADDRESSED. THE COMPLAINT COULD NOT BE CONFIRMED AND THE ROOT CAUSE IS UNDETERMINED. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. IF SAMPLES ARE RECEIVED IN THE FUTURE THE COMPLAINT WILL BE REOPENED FOR FURTHER INVESTIGATION. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH # 9231336 ALL INSPECTIONS WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WAS ONE (1) NOTIFICATION [(B)(4)] NOTED THAT DID NOT PERTAIN TO THE COMPLAINT. THERE WERE TWO (2) NOTIFICATIONS [(B)(4)] NOTED FOR CRACKED HUBS. THE INVESTIGATION CONCLUDED: UNCONFIRMED: BD WAS NOT ABLE TO DUPLICATE OR CONFIRM THE CUSTOMER¿S INDICATED FAILURE. BASED ON THE ABOVE, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME ROOT CAUSE DESCRIPTION: ROOT CAUSE CANNOT BE DETERMINED AT THIS TIME AS THE ISSUE IS UNCONFIRMED.

Description of Event or Problem · 1

IT WAS REPORTED THAT A SYRINGE 0.3ML 31GA 8MM 10BAG 500 WAL SEPARATED FROM THE HUB DURING USE. THE FOLLOWING WAS REPORTED BY THE INITIAL REPORTER: "IT WAS REPORTED THAT NEEDLE HUB SEPARATED. VERBATIM: CONSUMER REPORTED THAT THE NEEDLE HUB SEPARATED AND STAYED INSIDE OF THE SHIELD. THE SHIELD WAS NOT DIFFICULT TO REMOVE."

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1180404 SYRINGE 0.3ML 31GA 8MM 10BAG 500 WAL PISTON SYRINGE FMF BD MEDICAL - DIABETES CARE 328512 9231336 00681131311786

Patients

Seq Age Sex Outcome Treatment
1