SYRINGE 0.3ML 31GA 6MM WHOLEUNIT 10BAG
Report
- Report Number
- 1920898-2020-01375
- Event Type
- Malfunction
- Date Received
- October 7, 2020
- Date of Event
- September 17, 2020
- Report Date
- October 30, 2020
- Manufacturer
- BD MEDICAL - DIABETES CARE
- Product Code
- FMF
- UDI-DI
- 00382903249091
- PMA / PMN Number
- K024112
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS, US
- Reporter Occupation
- PHARMACIST
Narratives
THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D.10. DEVICE AVAILABLE FOR EVAL?: YES. D.10. RETURNED TO MANUFACTURER ON: 10/23/2020. H.6. INVESTIGATION: CUSTOMER RETURNED (4) LOOSE 3/10CC SYRINGES. CUSTOMER STATES THAT THE NEEDLE HUB SEPARATED WHEN REMOVING SHIELD, THE SHIELDS ARE DIFFICULT TO REMOVE, AND THEY ARE TIGHT. ALL RETURNED SYRINGES WERE EXAMINED AND ALL EXHIBITED THE HUB-NEEDLE/SHIELD ASSEMBLY SEPARATED FROM THE BARREL. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH # 0083503 ALL INSPECTIONS WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WERE ZERO (0) NOTIFICATIONS NOTED THAT PERTAINED TO THE COMPLAINT. PROCESS SUMMARY: AUTOMATIC SYRINGE ASSEMBLY MACHINE, WHICH FEEDS 3/10CC, SYRINGE COMPONENTS (BARREL, STOPPER, PLUNGER, NEEDLE ASSEMBLY & CAP) AND ASSEMBLES THESE COMPONENTS. THIS MACHINE CONSISTS OF A BARREL CLEANING DIAL, LUBRICATION DIAL, PLUNGER/STOPPER ASSEMBLY DIAL, SYRINGE ASSEMBLY DIAL, AND VARIOUS INSPECTIONS AND TRANSFER DIALS. DHR, L2L DISPATCHES, AND LOGBOOK ENTRIES WERE LOOKED AT, NOTHING PERTAINING TO THIS DEFECT WAS FOUND. ROOT CAUSE FOR THIS DEFECT CANNOT BE DETERMINED. CAPA#1630423 WAS INITIATED.
IT WAS REPORTED THAT SYRINGE 0.3ML 31GA 6MM WHOLEUNIT 10BAG NEEDLE HUB SEPARATED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 324909 BATCH NO. 0083503. IT WAS REPORTED THAT NEEDLE SHIELDS ARE TIGHT AND THE NEEDLE HUB SEPARATES.
DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED. (B)(4).
IT WAS REPORTED THAT SYRINGE 0.3ML 31GA 6MM WHOLEUNIT 10BAG NEEDLE HUB SEPARATED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 324909 BATCH NO. 0083503. IT WAS REPORTED THAT NEEDLE SHIELDS ARE TIGHT AND THE NEEDLE HUB SEPARATES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1104939 | SYRINGE 0.3ML 31GA 6MM WHOLEUNIT 10BAG | PISTON SYRINGE | FMF | BD MEDICAL - DIABETES CARE | 324909 | 0083503 | 00382903249091 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |