FDA Adverse Event Injury Summary report: N

NASAL PANCREATIC DRAINAGE SET

MDR report key: 10598591 · Received September 29, 2020

Report

Report Number
3001845648-2020-00671
Event Type
Injury
Date Received
September 29, 2020
Date of Event
May 14, 2020
Report Date
October 12, 2021
Manufacturer
COOK IRELAND LTD
Product Code
FGE
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER
Health Professional
N

Narratives

Additional Manufacturer Narrative · 0

PMA/510(K) # K171623. DEVICE EVALUATION THE NPDS-5 DEVICE OF UNKNOWN RPN AND LOT NUMBER INVOLVED IN THIS COMPLAINT WAS NOT AVAILABLE FOR EVALUATION. WITH THE INFORMATION PROVIDED, A DOCUMENT-BASED INVESTIGATION WAS CONDUCTED. LAB EVALUATION ¿ N/A. DOCUMENT REVIEW AS THE LOT NUMBER OF THE COMPLAINT STENTS ARE UNKNOWN, A REVIEW OF THE RELEVANT MANUFACTURING RECORDS CANNOT BE CONDUCTED. HOWEVER, PRIOR TO DISTRIBUTION ALL NPDS-5 DEVICES ARE SUBJECT TO VISUAL A VISUAL INSPECTION AND FUNCTIONAL CHECKS TO ENSURE DEVICE INTEGRITY. THESE INSPECTIONS AND FUNCTIONAL CHECKS ARE OUTLINED IN INTERNAL PROCEDURES IN PLACE AT CIRL. IT SHOULD BE NOTED THAT THE INSTRUCTIONS FOR USE (IFU0107-2) STATES THE FOLLOWING: ¿INTENDED USE THE NASAL PANCREATIC DRAINAGE SET IS USED FOR TEMPORARY ENDOSCOPIC DRAINAGE OF THE PANCREATIC DUCT THROUGH THE NASAL PASSAGE BY USE OF AN INDWELLING CATHETER.¿ ¿CONTRAINDICATIONS: CONTRAINDICATIONS INCLUDE THOSE SPECIFIC TO ERCP.¿ THERE IS EVIDENCE TO SUGGEST THE USER DID NOT FOLLOW THE IFU. IMAGE REVIEW ¿ N/A. ROOT CAUSE REVIEW A DEFINITIVE ROOT CAUSE OF OFF-LABEL USE WAS IDENTIFIED FROM THE AVAILABLE INFORMATION. FROM THE INFORMATION PROVIDED IT IS KNOWN THAT THE NPDS-5 DEVICE WAS USED IN PATIENT¿S WITH ALTERED ANATOMY. AS THERE IS NO INSTRUCTIONS FOR USING THESE DEVICES IN SURGICALLY ALTERED ANATOMY AND AS THE DEVICE WAS USED OUTSIDE OF ITS VALIDATED STATE, THIS IS CONSIDERED OFF-LABEL USE. SUMMARY: THE COMPLAINT IS CONFIRMED BASED ON CUSTOMER TESTIMONY. ACCORDING TO THE INITIAL REPORTER, (B)(6) PATIENTS SUFFERED PANCREATITIS, (B)(6) PATIENTS EXPERIENCE PANCREATIC LEAKAGES AND (B)(6) PATIENTS EXPERIENCED ABDOMINAL PAIN. COMPLAINTS OF THIS NATURE WILL CONTINUE TO BE MONITORED FOR POTENTIAL EMERGING TRENDS.

Description of Event or Problem · 0

SUPPLEMENTAL REPORT IS BEING SUBMITTED DUE TO THE COMPLETION OF THE INVESTIGATION.

Additional Manufacturer Narrative · 1

510(K): K171623. INVESTIGATION IS STILL PENDING, A FOLLOW UP MDR WILL BE SUBMITTED TO INCLUDE THE INVESTIGATION CONCLUSIONS.

Description of Event or Problem · 1

KOGURE ET AL 2020 ¿ENDOSCOPIC MANAGEMENT OF PANCREATIC DISEASES IN PATIENTS WITH SURGICALLY ALTERED ANATOMY: CLINICAL OUTCOMES OF COMBINATION OF DOUBLE-BALLOON ENDOSCOPY- AND ENDOSCOPIC ULTRASOUND-GUIDED INTERVENTIONS¿. THE CURRENT STUDY AIMED TO RETROSPECTIVELY EVALUATE THE FEASIBILITY, EFFECTIVENESS, AND SAFETY OF A COMBINATION OF DBE ASSISTED AND EUS-GUIDED PANCREATIC INTERVENTIONS IN PATIENTS WITH SURGICALLY ALTERED ANATOMY. A SINGLE-CENTER RETROSPECTIVE ANALYSIS OF PATIENTS WITH SURGICALLY ALTERED ANATOMY WHO UNDERWENT PANCREATIC INTERVENTIONS VIA SHORT DOUBLE-BALLOON ENDOSCOPE-ASSISTED ERP (DB-ERP) AND ENDOSCOPIC ULTRASONOGRAPHY- GUIDED PANCREATIC DUCT DRAINAGE (EUS-PD) BETWEEN OCTOBER 2006 AND JUNE 2019. SURGICALLY ALTERED ANATOMY UNDERGOING ENDOSCOPIC TREATMENT (DB-ERP, EUS-PD, OR BOTH) FOR PANCREATIC DISEASES WERE STUDIED. DB-ERP: SELECTIVE CANNULATION TO THE PANCREATIC DUCT WAS ATTEMPTED VIA A CONTRAST ASSISTED OR WIRE-GUIDED METHOD USING A STRAIGHT CANNULA (0.025-INCH ERCP CATHETER; MTW ENDOSKOPIE, WESEL,GERMANY) OR A ROTATABLE SPHINCTEROTOME (TRUETOME; BOSTON SCIENTIFIC, MARLBOROUGH, MA, USA) WITH A 0.035- OR 0.025-INCH HYDROPHILIC GUIDEWIRE (RADIFOCUS; TERUMO, TOKYO, JAPAN). IN CASES WITH SEVERE STRICTURE OR OBSTRUCTION OF THE PJ ANASTOMOSIS, A METAL-TIP CANNULA (PR-132Q; OLYMPUS) AND A 0.018-INCH HYDROPHILIC GUIDEWIRE (RADIFOCUS) WERE USED. SUBSEQUENTLY, THE GUIDEWIRE WAS REPLACED WITH A 0.025-INCH STIFF GUIDEWIRE(REVOWAVE; PIOLAX MEDICAL DEVICES, KANAGAWA, JAPAN) TO USE WIRE-GUIDED DEVICES, SUCH AS A BALLOON DILATION CATHETER, A BASKET CATHETER, AND AN EXTRACTION BALLOON CATHETER. THE DIAMETER OF THE DILATION BALLOON WAS SELECTED NOT EXCEEDING THAT OF THE PANCREATIC DUCT PROXIMAL TO THE STRICTURE. IF THE WAIST OF THE BALLOON DID NOT DISAPPEAR AND THE STRICTURE WAS CONSIDERED PERSISTENT, A 5- OR 7-FR TRANSANASTOMOTIC PANCREATIC STENT WAS INSERTED (GEENEN; COOK MEDICAL, BLOOMINGTON, IN, USA, FIG. 2). PANCREATIC STENT WAS EXCHANGED EVERY 3 MONTHS AND THE NUMBER OF STENTS WAS INCREASED, IF POSSIBLE, UNTIL THE STRICTURE RESOLUTION WAS CONFIRMED. PDSS WERE EXTRACTED USING BASKET AND EXTRACTION BALLOON CATHETERS IN A RETROGRADE MANNER FOLLOWING BALLOON DILATION OF THE ANASTOMOTIC STRICTURE OR AMPULLA.26 IN PATIENTS WITH PF, A 5-FR NASOPANCREATIC CATHETER WAS PLACED (NPDS-5; COOK MEDICAL). EUS-PD: A 0.025-INCH GUIDEWIRE (VISIGLIDE2; OLYMPUS) WAS INTRODUCED INTO THE PANCREATIC DUCT, AND IF POSSIBLE, PASSED THE STRICTURE INTO THE JEJUNUM. AFTER DILATION OF THE PANCREATICOGASTROSTOMY TRACT USING A 4-MM BALLOON CATHETER AND/OR A CAUTERY DILATOR, A 5- OR 7-FR TRANS-MURAL PANCREATIC STENT (GEENEN, COOK MEDICAL; ZIMMON, COOK MEDICAL; FLEXIMA, BOSTON SCIENTIFIC; OR THROUGH & PASS, GADELIUS MEDICAL, TOKYO, JAPAN) OR A 5- FR NASOPANCREATIC CATHETER WAS INSERTED IN AN ANTEGRADE MANNER (FIG. 3). IN PATIENTS WITH PJAS, A PANCREATIC STENT WAS PLACED ACROSS THE STRICTURE, IF POSSIBLE. PDS WAS ANTEGRADELY PUSHED OUT USING AN EXTRACTION BALLOON CATHETER. PRIOR SURGERY AND GASTROINTESTINAL RECONSTRUCTION WERE PANCREATICODUODENECTOMY (PD) WITH BILLROTH-II IN 26 (45.0%), PD WITH ROUX-EN-Y (R-Y) IN 10 (25.0%), PD WITH IMANAGA METHOD IN ONE (2.5%), AND DISTAL GASTRECTOMY WITH R-Y IN THREE (7.5%). PANCREATICOJEJUNOSTOMY ANASTOMOTIC STRICTURE WAS TREATED BY BALLOON DILATION ALONE IN 11 PATIENTS AND BALLOON DILATION WITH STENT PLACEMENT IN 18 PATIENTS. THE RATE OF STRICTURE RESOLUTION VIA PLASTIC STENT PLACEMENT WAS 33.3% (6/18) WITH A MEDIAN STENT INDWELLING TIME OF 9.6 MONTHS (IQR, 6.6¿13.1 MONTHS). STRICTURE RECURRENCE AFTER STENT REMOVAL WAS OBSERVED IN THREE PATIENTS (50%) AFTER 3.3, 7.6, AND 13.6 MONTHS FROM STENT REMOVAL, WHICH WAS MANAGED BY PLASTIC STENT PLACEMENT AGAIN. PF WAS MANAGED WITH NASOPANCREATIC CATHETER AND PLASTIC STENT PLACEMENT IN 28.5% (2/7) AND 42.9% (3/7), RESPECTIVELY. ADVERSE EVENTS WERE OBSERVED IN 12.2% (5/41) AFTER DBERP: ONE PERFORATION (MODERATE, 1) AND FOUR PANCREATITIS (MODERATE, 3; MILD, 1). IN ONE PATIENT WITH PERFORATION, PNEUMOPERITONEUM WAS OBSERVED ON FLUOROGRAPHY DURING PANCREATIC CANNULATION USING A METAL-TIP CANNULA. A 5-FR CATHETER WAS LEFT IN THE AFFERENT LIMB TO AVOID LEAKAGE OF BILE AND PANCREATIC JUICE, AND THE PATIENT REMAINED ASYMPTOMATIC WITHOUT SUBSEQUENT PERITONITIS. TOGETHER WITH SEVEN SALVAGE PROCEDURES, THE ADVERSE EVENT RATE OF EUS-PD WAS 55.6% (5/9): THREE PANCREATIC LEAKAGE (MODERATE, 2; MILD, 1) AND TWO ABDOMINAL PAIN (MILD, 2). RPN: NPDS-5: THIS FILE IS BEING CREATED TO CAPTURE THE 4 PATIENTS WHO SUFFERED PANCREATITIS, 3 PATIENTS WITH PANCREATIC LEAK AND TWO WITH ABDOMINAL PAIN WITH NPDS-5. THIS FILE IS ALSO RELATED TO OFF LABEL USE AS THE STENT WAS PLACED IN ALTERED ANATOMY. IT IS UNKNOWN WHETHER THESE ADVERSE EVENTS OCCURRED WITH GEENEN, ZIMMON OR NPDS-5 THEREFORE A FILE HAS BEEN CREATED TO CAPTURE EACH DEVICE. AN ADDITIONAL COMPLAINT WAS CREATED TO CAPTURE GENERAL OFF LABEL NPDS-5 DEVICES THAT DID NOT RESULT IN AN AE. (THE LITERATURE INDICATES THAT NPDS-5 WAS PLACED IN PATIENTS WITH PF IN THE DB-ERP GROUP AND USED IN EUS-PD GROUP. AS PER TABLE 2, 8 PATIENTS WERE TREATED FOR PF IN DB-ERP GROUP AND 9 PATIENTS WERE TREATED IN EUS-PD. NPDS-5 WAS POTENTIALLY USED IN 17 PATIENTS).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1063625 NASAL PANCREATIC DRAINAGE SET FGE CATHETER, BILIARY, DIAGNOSTIC FGE COOK IRELAND LTD UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 66 YR Male Required Intervention