FDA Adverse Event Malfunction Summary report: N

90 DEGREE SCREWDRIVER T-HANDLE

MDR report key: 10581224 · Received September 24, 2020

Report

Report Number
2939274-2020-04314
Event Type
Malfunction
Date Received
September 24, 2020
Report Date
September 1, 2020
Manufacturer
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
Product Code
HWE
UDI-DI
10887587071671
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MN, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H6: THE DEVICE WAS RECEIVED, THE INVESTIGATION IS IN PROGRESS, NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

DEPUY SYNTHESE IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHESE HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHESE OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHESE, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF THE INFORMATION IS UNKNOWN, NOT AVAILABLE OR DOES NOT APPLY, THE SECTION/FIELD OF THE FORM IS LEFT BLANK. H10 ADDITIONAL NARRATIVE: H3, H4, H6- VISUAL INSPECTION RESULTS PART NUMBER: SD03.505.005 LOT NUMBER: 9921206 PRODUCT WAS RECEIVED WITH ONE OF THE TWO PIN COMPONENTS (SD03.505.005.05) HEAVILY BENT/DEFORMED. THE OTHER PIN WAS SLIGHTLY DEFORMED. A DENT WAS OBSERVED ON THE CHAMFER OF THE 90 DEGREE SCREWDRIVER BODY (SD03.505.005.01) NEAR THE LOCATION OF THE BENT PIN COMPONENT. THERE WAS NO EVIDENCE OF PHYSICAL DEVICE BREAKAGE SO THE REPORTED CONDITION OF BROKEN WAS NOT CONFIRMED. THE COMPLAINT CONDITION OF "DEFORMED/BENT" WAS CONFIRMED, AS IT MATCHES THE REPORTED CONDITION, BUT UPON FURTHER ANALYSIS IT WAS DETERMINED NOT TO BE RELATED TO THE MANUFACTURING PROCESS FOR THE FOLLOWING REASON: THE PRODUCT PASSED ALL INSPECTION CRITERIA (100% VISUAL AND CTQ FEATURES) AND WAS FOUND TO BE WITHIN SPECIFICATIONS AT THE TIME IT WAS RELEASED TO THE WAREHOUSE. THE CERTIFICATE OF COMPLIANCE FROM SUPPLIER ISIMAC CERTIFIES THAT ALL PRODUCT WAS MANUFACTURED IN ACCORDANCE WITH THE PRODUCT DRAWING AND NO NONCONFORMANCE'S RELATED TO THE COMPLAINT CONDITION WERE PRESENT FOR THE COMPLAINANT LOT. DURING THE INVESTIGATION NO UNIDENTIFIED PRODUCT DESIGN/MANUFACTURING ISSUES OR DISCREPANCIES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. DEVICE HISTORY LOT PART #: SD03.505.005 SYNTHESE LOT #: 9921206 MANUFACTURING SITE: SYNTHESE BRANDYWINE RELEASE TO WAREHOUSE DATE: (B)(6) 2016 REVIEW OF THE DEVICE HISTORY RECORD(S) SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THIS PRODUCT, AND ANY SUB-COMPONENTS, WHICH WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 1

REPORTER IS COMPANY REPRESENTATIVE. THE DEVICE WAS RECEIVED, THE INVESTIGATION IS IN PROGRESS, NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

IT WAS REPORTED THAT ON (B)(6) 2020, AN INVENTORY CHECK OCCURRED AND MULTIPLE DEVICES INCLUDING A MESH CUTTER, RIGHT ANGLE BENDER, PLATE CUTTER, 90 DEGREE SCREWDRIVER T-HANDLE, HANDLE FOR 90° SCREWDRIVER, SHAFT FOR 90° SCREWDRIVER, AND MATRIXRIB SCREWDRIVER BLADE SELF-RETAINING F/90° SCREWDRIVER WERE FOUND WITH MALFUNCTIONS. WHEN TESTED, THE DEVICES WOULD NOT WORK PROPERLY; WOULD NOT TURN, HOLD SCREWS, AND SOME WERE STRIPPED. SOME INSTRUMENTS WERE BENT OR DULL. THERE WAS NO PATIENT OR PROCEDURE INVOLVEMENT. (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1048229 90 DEGREE SCREWDRIVER T-HANDLE INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT HWE WRIGHTS LANE SYNTHES USA PRODUCTS LLC SD03.505.005 A7GA27 10887587071671

Patients

Seq Age Sex Outcome Treatment
1