SMALLBORE 6 INCH EXT VLV
Report
- Report Number
- 9616066-2020-02864
- Event Type
- Malfunction
- Date Received
- September 22, 2020
- Date of Event
- August 30, 2020
- Report Date
- September 2, 2020
- Manufacturer
- SISTEMAS MEDICOS ALARIS, S.A. DE C.
- Product Code
- FPA
- UDI-DI
- 07613203011952
- PMA / PMN Number
- K960280
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
THE FOLLOWING FIELDS WERE UPDATED DUE TO ADDITIONAL INFORMATION: D10: DEVICE AVAILABLE FOR EVAL YES. D10: RETURNED TO MANUFACTURER ON: 09/10/2020. INVESTIGATION CONCLUSION : THE CUSTOMER REPORTED ¿WHEN A SYRINGE IS SCREWED ONTO THE LUER LOCK, THE PLUNGER IS NOT DEPRESSING ENOUGH TO ALLOW FLUID THROUGH¿. RECEIVED FROM THE CUSTOMER WAS ONE USED EXTENSION SET MODEL 20039E LOT 20075476 WITH ITS ORIGINAL PACKAGE. THE SET WAS VISUALLY INSPECTED FOR KINKS, INCOMPLETE BONDING ENGAGEMENTS, HOLES/TEARS IN THE TUBING OR DAMAGES TO THE COMPONENTS. NO ABNORMALITIES WERE OBSERVED DURING VISUAL INSPECTION. TO PREPARE THE SET FOR FUNCTIONAL TESTING A LAB EXTENSION SET WAS ATTACHED TO THE SET¿S MALE LUER TO TEST THE CONNECTION. AN 18 GAUGE BLUNT CANNULA WAS ATTACHED TO THE END OF THE LAB EXTENSION SET TO CLOSELY SIMULATE HOW THE SET WOULD BE USED IN THE FIELD. FUNCTIONAL TESTING WAS PERFORMED BY FILLING A LAB 10ML BD SYRINGE WITH BLUE-DYED WATER AND ATTACHING IT TO THE SET¿S SMARTSITE. THE SYRINGE PLUNGER WAS DEPRESSED AND THE FLUID WAS OBSERVED TO FLOW THROUGH THE SET AND PRIMED COMPLETELY. THE SYRINGE WAS REPEATEDLY CONNECTED AND DISCONNECTED FROM THE SMARTSITE WITH THE SYRINGE PLUNGER REPEATEDLY BEING DEPRESSED. NO OCCLUSIONS, LEAKING, OR OTHER ISSUES WERE OBSERVED DURING TESTING. THE DEVICE HISTORY RECORD FOR EXTENSION SET MODEL 20039E LOT 20075476 WAS PERFORMED. THE SEARCH SHOWED A TOTAL OF 12,000 UNITS IN 1 LOT WERE BUILT ON 07 JULY 2020. THERE WERE NO RELATED QN¿S (QUALITY NOTIFICATIONS) ISSUED DURING THE PRODUCTION BUILD OF THIS SET FOR THE FAILURE MODE REPORTED FOR THE GIVEN TIME FRAME. THE CUSTOMER¿S REPORT OF WHEN A SYRINGE IS SCREWED ONTO THE LUER LOCK, THE PLUNGER IS NOT DEPRESSING ENOUGH TO ALLOW FLUID THROUGH WAS NOT CONFIRMED ON EXTENSION SET MODEL 20039E. THE ROOT CAUSE OF THE CUSTOMER¿S REPORT OF THE PLUNGER IS NOT DEPRESSING ENOUGH TO ALLOW FLUID THROUGH COULD NOT BE DETERMINED AS WE WERE UNABLE TO REPLICATE THE REPORTED EVENT DURING FUNCTIONAL TESTING. H3 OTHER TEXT : SEE H10.
IT WAS REPORTED THAT THE SMALLBORE 6 INCH EXT VLV WAS CLOGGED/BLOCKED/OCCLUDED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE BD EXTENSION SET SMALLBORE TUBING(WE REFER TO THIS ITEM AS "J-LOOPS") WE HAVE BEEN GETTING AT OUR ER HAVE BEEN NOT WORKING AS WELL AS IN THE PAST. LATELY WHEN A SYRINGE IS SCREWED ONTO THE LUER-LOK, THE BLUE PLUNGER IS NOT BEING DEPRESSED ENOUGH TO ALLOW FLUID TO THRU IT. THE NURSES HAVE BEEN REMOVING THE J-LOOP AND REPLACING IT WITH A NEW ONE, ONLY TO HAVE THE SAME ISSUE. THE J-LOOPS ARE NOT ALL FROM THE SAME BOX OR CASE. I WAS ABLE TO GET THE J-LOOPS TO WORK BY REPEATEDLY SCREWING A SYRINGE ONTO THE LUER-LOK END A COUPLE OF TIMES. I GUESSING THAT IF WE ARE HAVING TROUBLE, THEN ALL YOUR CUSTOMERS WHO USE THESE ARE HAVING TROUBLE. DATE OF FAILURE: AUGUST 30TH.
A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED THAT THE SMALLBORE 6 INCH EXT VLV WAS CLOGGED/BLOCKED/OCCLUDED. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: THE BD EXTENSION SET SMALLBORE TUBING(WE REFER TO THIS ITEM AS "J-LOOPS") WE HAVE BEEN GETTING AT OUR ER HAVE BEEN NOT WORKING AS WELL AS IN THE PAST. LATELY WHEN A SYRINGE IS SCREWED ONTO THE LUER-LOK, THE BLUE PLUNGER IS NOT BEING DEPRESSED ENOUGH TO ALLOW FLUID TO THRU IT. THE NURSES HAVE BEEN REMOVING THE J-LOOP AND REPLACING IT WITH A NEW ONE, ONLY TO HAVE THE SAME ISSUE. THE J-LOOPS ARE NOT ALL FROM THE SAME BOX OR CASE. I WAS ABLE TO GET THE J-LOOPS TO WORK BY REPEATEDLY SCREWING A SYRINGE ONTO THE LUER-LOK END A COUPLE OF TIMES. I GUESSING THAT IF WE ARE HAVING TROUBLE, THEN ALL YOUR CUSTOMERS WHO USE THESE ARE HAVING TROUBLE. DATE OF FAILURE: (B)(6).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1033382 | SMALLBORE 6 INCH EXT VLV | INTRAVASCULAR ADMINISTRATION SET | FPA | SISTEMAS MEDICOS ALARIS, S.A. DE C. | 20075476 | 07613203011952 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other | 302995, 20200830| 302995, 20200830 |