FDA Adverse Event Malfunction Summary report: N

STERILE FX25REC W/RES

MDR report key: 10521632 · Received September 11, 2020

Report

Report Number
1124841-2020-00217
Event Type
Malfunction
Date Received
September 11, 2020
Date of Event
August 26, 2020
Report Date
November 16, 2020
Manufacturer
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
Product Code
DTZ
UDI-DI
00699753450820
PMA / PMN Number
K151791
Removal / Correction Number
1124841-10/30/2020-002-R
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS SUBMITTED TO FDA IN ACCORD WITH APPLICABLE REGULATIONS ¿ AND AS INDICATED BY TERUMO CARDIOVASCULAR SYSTEMS IN THE INITIAL REPORT SUBMITTED TO THE FDA ON SEPTEMBER 11, 2020. UPON FURTHER INVESTIGATION OF THE REPORTED EVENT, THE FOLLOWING INFORMATION IS NEW AND/OR CHANGED: H3 (DEVICE EVALUATION ANTICIPATED BY MANUFACTURER - A SECOND FOLLOW-UP WILL BE SUBMITTED UPON COMPLETION OF THE INVESTIGATION AND/OR SUBMISSION OF NEW INFORMATION, THUS TCVS REFERENCES CONCLUSIONS CODE 11.) ALL AVAILABLE INFORMATION HAS BEEN PLACED ON FILE IN QUALITY MANAGEMENT FOR APPROPRIATE TRACKING, TRENDING, AND FOLLOW-UP.

Additional Manufacturer Narrative · 0

THIS FOLLOW-UP REPORT IS SUBMITTED DUE TO TERUMO CARDIOVASCULAR SYSTEMS ISSUING A FIELD REMOVAL, 1124841-10/30/2020-002-R. THIS FOLLOW-UP REPORT IS SUBMITTED TO FDA IN ACCORD WITH APPLICABLE REGULATIONS. METHOD CODE #1: 10 - TESTING OF ACTUAL/SUSPECTED DEVICE. METHOD CODE #2: 3331 - ANALYSIS OF PRODUCTION RECORDS. RESULTS CODE: 706 - ASSEMBLY PROBLEM IDENTIFIED. CONCLUSIONS CODE: 25 - CAUSE TRACED TO MANUFACTURING. THE AFFECTED SAMPLES WERE INSPECTED UPON RECEIPT TO CONFIRM THE EVENT. ROOT CAUSE ANALYSIS ACTIVITIES HAVE IDENTIFIED ASSOCIATE ERROR/FAILURE TO FOLLOW PROCEDURE AS THE IMMEDIATE CAUSE OF THE CONFIGURATION MIX-UP. AN ASSOCIATE PROVIDED THE INCORRECT CONFIGURATION OF OXYGENATOR TO THE ASSEMBLY LINE BY CHOOSING THE WRONG TOTE OF PRODUCT FROM A STAGING AREA AND THEN DIDN'T DETECT THE ERROR DURING DOWNSTREAM VISUAL INSPECTION. CAPA 8D-01225 IS IN PROCESS AND WILL IDENTIFY STRONGER CONTROLS FOR TOTE SELECTION AND DOWNSTREAM VERIFICATION WILL BE MANAGED VIA ENGINEERING CONTROLS. ALL AVAILABLE INFORMATION HAS BEEN PLACED ON FILE IN QUALITY MANAGEMENT FOR APPROPRIATE TRACKING, TRENDING, AND FOLLOW-UP.

Description of Event or Problem · 0

ON OCTOBER 30, 2020, TERUMO CARDIOVASCULAR SYSTEMS ISSUED A FIELD REMOVAL, 1124841-10/30/2020-002-R.

Additional Manufacturer Narrative · 1

TERUMO HAS NOT RECEIVED THE DEVICE FOR EVALUATION; THEREFORE, THE INVESTIGATION HAS YET TO BE COMPLETED. TERUMO PLANS ON SUBMITTING A FOLLOW-UP REPORT WHEN THE INVESTIGATION IS COMPLETE AND WHEN MORE INFORMATION BECOMES AVAILABLE. (B)(4).

Description of Event or Problem · 1

THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING AN OUT OF BOX, AN INCORRECT OXYGENATOR ASSEMBLY WAS RECEIVED. NO PATIENT INVOLVEMENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
985272 STERILE FX25REC W/RES BLOOD GAS OXYGENATOR DTZ TERUMO CARDIOVASCULAR SYSTEMS CORPORATION 3CX*FX25REC YD23 00699753450820

Patients

Seq Age Sex Outcome Treatment
1