FDA Adverse Event Malfunction Summary report: N

RI WITNESS,SIT ON TOP,

MDR report key: 10516341 · Received September 10, 2020

Report

Report Number
1216677-2020-00204
Event Type
Malfunction
Date Received
September 10, 2020
Date of Event
June 29, 2020
Report Date
March 3, 2023
Manufacturer
COOPERSURGICAL, INC.
Product Code
MQG
PMA / PMN Number
K160504
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
UK
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL
Health Professional
Yes

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION: DISTRIBUTION HISTORY: THE COMPLAINT PRODUCT WAS MANUFACTURED AT CSI ON 11/FEB/2020. MANUFACTURING RECORD REVIEW: DEVICE HISTORY RECORD WAS REVIEWED, AND NO NON-CONFORMITIES RELATED TO THE COMPLAINT CONDITION WERE NOTED. INCOMING INSPECTION REVIEW: INCOMING INSPECTION RECORD REVIEW NOT APPLICABLE TO THIS PRODUCT. SERVICE HISTORY RECORD : SERVICE HISTORY NOT APPLICABLE FOR THIS PRODUCT. HISTORICAL COMPLAINT REVIEW: A REVIEW OF THE 2-YEAR COMPLAINT HISTORY DID NOT SHOW SIMILAR REPORTED COMPLAINT CONDITIONS. PRODUCT RECEIPT: THE COMPLAINT PRODUCT HAS NOT BEEN RETURNED TO COOPERSURGICAL AS THIS IS A FIELD SERVICE COMPLAINT. VISUAL EVALUATION: THIS IS A FIELD SERVICE COMPLAINT, THERE WAS NO PRODUCT RETURNED FOR EVALUATION. IF FURTHER INFORMATION BECOMES AVAILABLE AT A LATER DATE THIS INVESTIGATION WILL BE AMENDED ACCORDINGLY. FUNCTIONAL EVALUATION: THIS IS A FIELD SERVICE COMPLAINT, THERE WAS NO PRODUCT RETURNED FOR EVALUATION. IF FURTHER INFORMATION BECOMES AVAILABLE AT A LATER DATE THIS INVESTIGATION WILL BE AMENDED ACCORDINGLY. ROOT CAUSE: THIS IS A FIELD SERVICE COMPLAINT, THERE WAS NO PRODUCT RETURNED FOR EVALUATION. IF FURTHER INFORMATION BECOMES AVAILABLE AT A LATER DATE THIS INVESTIGATION WILL BE AMENDED ACCORDINGLY. LIKELY ROOT CAUSE CAN BE ATTRIBUTED TO MODERN LOW VOLTAGE ELECTRONIC EQUIPMENT WHICH IS MOST COMMONLY POWERED BY SWITCHING POWER SUPPLIES (PSUS) (E.G. LAPTOP/TABLET POWER SUPPLIES, USB CHARGERS, ETC). THESE ARE OFTEN UNGROUNDED TYPES, WHICH MEANS THAT THERE IS NO DIRECT CONNECTION TO EARTH. PROTECTION AGAINST ELECTRIC SHOCK IS PROVIDED BY MEANS OF ISOLATION BETWEEN THE MAINS INPUT AND THE LOW VOLTAGE OUTPUT, INSTEAD OF BY USING AN EARTH CONNECTION. AS THERE IS NO DIRECT CONNECTION TO EARTH, A CHARGE CAN BUILD UP ON THE OUTPUT OF THE POWER SUPPLY. DEPENDING ON THE DESIGN OF THE POWER SUPPLY, THIS CAN BE TO A SUFFICIENT LEVEL TO CAUSE A TINGLING SENSATION, OR A SIMILAR SENSATION TO A STATIC ELECTRICITY SHOCK WHEN INITIALLY TOUCHING A CONDUCTIVE PART OF THE DEVICE (OR A CONNECTED DEVICE). CORRECTIVE ACTION: THE ACTION IS TO CHANGE THE TABLET POWER SUPPLY AND USB HUB TO AN ALTERNATIVE TYPE (SURFACE PRO DOCKING STATION). SUBSEQUENT MEASUREMENTS, USING THE SURFACE PRO DOCKING STATION, INDICATE THAT THE LEVEL OF CHARGE IS LOW ENOUGH NOT TO BE FELT BY THE USER. COOPERSURGICAL WILL CONTINUE TO MONITOR THIS COMPLAINT CONDITION FOR ANY TRENDS.

Description of Event or Problem · 0

REPORT SUBMITTED ON BEHALF OF CARE FERTILITY MANCHESTER. "A COUPLE OF THE EMBRYOLOGISTS HAVE MENTIONED TO ME TODAY THAT THEY GET A SMALL ELECTRIC SHOCK FROM THE METAL STRIP AT THE BASE OF THE RI WITNESS PLATES, IF THEY REST THEIR ARM AT THE EDGE OF THE PLATE. THIS SEEMS TO BE AFFECTING THE LEFT SIDE OF THE ICSI HOOD AND THE RIGHT SIDE OF THE FREEZING HOOD." THE UNIT IS PLUGGED DIRECTLY TO THE LAB WALL SOCKET. (NOT VIA ANY OTHER EQUIPMENT) AN ENGINEER HAS BEEN PREPPED BY THE DESIGN TEAM TO VISIT AND FAULT FIND . REF:(B)(4). RI WITNESS SIT ON TOP 6-70-807-(B)(4).

Additional Manufacturer Narrative · 1

COOPERSURGICAL , INC. IS CURRENTLY INVESTIGATING THE REPORTED CONDITION.

Description of Event or Problem · 1

REPORT SUBMITTED BY RI ON BEHALF OF CARE FERTILITY (B)(4)- PER FCIF "A COUPLE OF THE EMBRYOLOGISTS HAVE MENTIONED TO ME TODAY THAT THEY GET A SMALL ELECTRIC SHOCK FROM THE METAL STRIP AT THE BASE OF THE RI WITNESS PLATES, IF THEY REST THEIR ARM AT THE EDGE OF THE PLATE. THIS SEEMS TO BE AFFECTING THE LEFT SIDE OF THE ICSI HOOD AND THE RIGHT SIDE OF THE FREEZING HOOD." THE UNIT IS PLUGGED DIRECTLY TO THE LAB WALL SOCKET. (NOT VIA ANY OTHER EQUIPMENT) AN ENGINEER HAS BEEN PREPPED BY THE DESIGN TEAM TO VISIT AND FAULT FIND. (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
983681 RI WITNESS,SIT ON TOP, RI WITNESS,SIT ON TOP, MQG COOPERSURGICAL, INC. 6-70-807 N/A

Patients

Seq Age Sex Outcome Treatment
1 Unknown Other