EDWARDS CERTITUDE INTRODUCER SHEATH SET, 18F
Report
- Report Number
- 2015691-2020-12811
- Event Type
- Death
- Date Received
- July 30, 2020
- Date of Event
- May 29, 2020
- Report Date
- July 23, 2020
- Manufacturer
- EDWARDS LIFESCIENCES
- Product Code
- NPT
- PMA / PMN Number
- P140031
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
SUPPLEMENTAL REPORT TO ADD NOE STATEMENT IN B5 SECTION, AND PROVIDE D5, AND H6 INFORMATION.
THIS REPORT SUMMARIZE <NOE> 1 </NOE> EVENT OF TRANSAPICAL RELATED DEATH EVENT FOR THE SAPIEN 3 FOR (B)(6) 2020.
EXEMPTION NUMBER E2016006, THIS REPORT SUMMARIZES 1 TRANSAPICAL RELATED EVENT FOR THE SAPIEN 3 VALVE IN THE AORTIC POSITION. THE ¿TIME TO EVENT¿ (TTE, IN DAYS) FOR THIS EVENT WAS 0. THE DEVICE IDENTIFICATION (DI) NUMBERS FOR EDWARDS CERTITUDE INTRODUCER SHEATH SET ARE: (B)(4). PER THE INSTRUCTIONS FOR USE (IFU), ACCESS SITE COMPLICATIONS/CARDIOVASCULAR INJURY, INCLUDING PERFORATION OF THE VENTRICLE OR MYOCARDIUM, BLEEDING, AND INJURY AT THE SITE OF VENTRICULAR ACCESS THAT MAY REQUIRE REPAIR ARE POTENTIAL COMPLICATIONS ASSOCIATED WITH THE TRANSAPICAL THV PROCEDURE. PER LITERATURE REVIEW, RISK FACTORS FOR APICAL LACERATION AND BLEEDING INCLUDE FRIABLE TISSUE, FATTY APEX, CHRONIC STEROID USE, DILATED LV WITH THINNED WALLS, AND HYPERTENSION DURING REMOVAL OF THE SHEATH. WHILE PATIENT CHARACTERISTICS ARE IMPORTANT, ACHIEVING GOOD HEMOSTATIC CONTROL OF THE LV APEX IS ONE OF THE MOST CRITICAL STEPS IN ENSURING THE SUCCESS OF THE TRANSAPICAL PROCEDURE, PARTICULARLY IN THE ELDERLY WITH FRIABLE TISSUE. ADDITIONAL LITERATURE REVIEW CONFIRMS THERE IS A HIGHER INCIDENCE OF APICAL BLEEDING IN FEMALE PATIENTS AND PATIENTS OVER 80 YEARS OLD. THIS INFORMATION CORRELATES WITH REVIEW OF COMPLAINT HISTORY, REVEALING THAT THE MAJORITY OF APICAL BLEEDING COMPLICATIONS APPEAR TO BE RELATED TO SURGICAL TECHNIQUE AND/OR DISEASED VENTRICLES DURING THE INSERTION OR REMOVAL OF THE SHEATH. THE THV TRAINING MANUALS NOTE THAT REMOVAL OF THE SHEATH AND ATTEMPTED CLOSURE OF THE APICAL INCISION MAY BE ASSOCIATED WITH BLOOD LOSS. RAPID BURST PACING CAN BE USED TO LOWER THE SYSTEMIC BLOOD PRESSURE DURING SHEATH REMOVAL AND APICAL CLOSURE. THE THV TRAINING MANUALS ALSO RECOMMEND THE PHYSICIAN CONSIDER PERFORMING THE PROCEDURE UNDER FULL CPB SUPPORT FOR CERTAIN PATIENTS, INCLUDING THOSE WITH CARDIOGENIC SHOCK (CARDIAC INDEX < 2 L/MIN PER SQUARE METER) DESPITE VOLUME CHALLENGE AND INOTROPIC SUPPORT, PROFOUND LV, RV, OR BIVENTRICULAR DYSFUNCTION, AND NOTABLY FRIABLE APEX. IN THIS CASE, SPECIFIC PROCEDURAL DETAILS WERE NOT AVAILABLE TO DETERMINE POTENTIAL CONTRIBUTING FACTORS. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS MONTHLY, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED.
THV/TVT REGISTRY SUMMARY REPORTING FOR ADVERSE EVENT SUBMISSION FOR (B)(6) 2020 DATA EXTRACT FOR AORTIC DEATH EVENTS FOR THE SAPIEN 3 VALVE. THIS REPORT SUMMARIZES 1 EVENT OF TRANSAPICAL RELATED DEATH EVENT FOR THE SAPIEN 3 TRANSCATHETER HEART VALVE FOR (B)(6) 2020. THE AGE RANGE FOR THIS EVENT IS 85. THE BREAKDOWN FOR GENDER IS AS FOLLOWS: 1 MALE. (B)(6) 2020 DATA EXTRACT INCLUDES DATA PROVIDED BY ACC FOR Q4 2019 (OCTOBER 1 ¿ DECEMBER 31).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 809659 | EDWARDS CERTITUDE INTRODUCER SHEATH SET, 18F | AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY | NPT | EDWARDS LIFESCIENCES | 9600IS18 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 85 YR | Death |