SYRINGE 0.5ML 31GA 8MM 10 BAG 500 WAL
Report
- Report Number
- 1920898-2020-00909
- Event Type
- Malfunction
- Date Received
- July 21, 2020
- Date of Event
- July 13, 2020
- Report Date
- July 15, 2020
- Manufacturer
- BD MEDICAL - DIABETES CARE
- Product Code
- FMF
- UDI-DI
- 00681131311762
- PMA / PMN Number
- K024112
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. MEDICAL DEVICE EXPIRATION DATE: NA. INVESTIGATION SUMMARY: LEVEL A INVESTIGATION - COMPLAINT EVALUATION / COMPLAINT HISTORY CHECK FOR THE EVENT(S) THAT OCCURRED. SEVERITY: S_1__; OCCURRENCE: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 1ST RELATED COMPLAINT FOR SHIELD DOES NOT DETACH AS INTENDED AND NEEDLE HUB SEPARATES ON LOT # 9231073. A REVIEW OF RISK MANAGEMENT 150RMN-0001-16 REVISION 13 INDICATES THAT THE POTENTIAL RISK OF THIS SPECIFIC REPORTED INCIDENT (SYRINGE, SHIELD DOES NOT DETACH AS INTENDED, NEEDLE HUB SEPARATES) WAS CAPTURED AND ADDRESSED APPROPRIATELY. INVESTIGATION SUMMARY: NO SAMPLES (INCLUDING PHOTOS) WERE RETURNED THEREFORE THE COMPLAINT COULD NOT BE CONFIRMED. IF SAMPLES ARE RECEIVED IN THE FUTURE THE COMPLAINT WILL BE REOPENED FOR FURTHER INVESTIGATION. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH# 9231073. ALL INSPECTIONS AND CHALLENGES WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WAS ONE (1) NOTIFICATION [200843441] NOTED THAT DID NOT PERTAIN TO THE COMPLAINT. THERE WAS ONE (1) NOTIFICATION [200842833] NOTED FOR RAISED HUBS. THERE WAS ONE (1) NOTIFICATION [200833554] NOTED FOR OUT OF SPEC SHIELD PULL. INVESTIGATION CONCLUSION: AS NO SAMPLES AND/OR PHOTO(S) WERE RECEIVED THE INVESTIGATION CONCLUDED: - UNCONFIRMED: BD WAS NOT ABLE TO DUPLICATE OR CONFIRM THE CUSTOMER¿S INDICATED FAILURE AS NO SAMPLES OR PHOTOS WERE RETURNED COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS. ROOT CAUSE DESCRIPTION: ROOT CAUSE CANNOT BE DETERMINED AT THIS TIME AS THE ISSUE IS UNCONFIRMED AS NO SAMPLES OR PHOTOS WERE RETURNED. RATIONALE: BASED ON THE INVESTIGATION, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME.
IT WAS REPORTED THAT SYRINGE 0.5ML 31GA 8MM 10 BAG 500 WAL HUB SEPARATED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 328509 BATCH NO. 9231073 IT WAS REPORTED THAT NEEDLE SHIELD WAS DIFFICULT TO REMOVE AND NEEDLE HUB SEPARATES AND STAYS INSIDE OF SHIELD. VERBATIM: CONSUMER REPORTED NEEDLE SHIELD DIFFICULT TO REMOVE. ALSO STATED THAT THE NEEDLE HUB SEPARATES AND STAYS INSIDE OF THE SHIELD.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 770198 | SYRINGE 0.5ML 31GA 8MM 10 BAG 500 WAL | PISTON SYRINGE | FMF | BD MEDICAL - DIABETES CARE | 328509 | 9231073 | 00681131311762 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |