NOVOSYN QUICK UNDY 5/0(1)70CM DS16(M)DDP
Report
- Report Number
- 3003639970-2020-00228
- Event Type
- Malfunction
- Date Received
- July 2, 2020
- Report Date
- August 11, 2020
- Manufacturer
- B. BRAUN SURGICAL, S.A.
- Product Code
- GAM
- PMA / PMN Number
- SEE H10
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AJ
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
ANALYSIS AND RESULTS: THERE ARE NO PREVIOUS COMPLAINTS OF THIS CODE BATCH OF WHICH WE MANUFACTURED AND DISTRIBUTED IN THE MARKET (B)(4) UNITS. THERE ARE NO UNITS IN STOCK IN B. BRAUN SURGICAL'S WAREHOUSE. WE HAVE RECEIVED A PICTURE SHOWING A NEEDLE DETACHED FROM THE THREAD AND THE THREAD BROKEN IN SEVERAL PIECES. THIS PICTURE IS ALSO FOR ANOTHER COMPLAINT RECEIVED FROM THE SAME END CUSTOMER BUT DIFFERENT BATCH SO IT IS NOT CONFIRMED FOR WHICH COMPLAINT CORRESPOND THE PICTURE RECEIVED. AS NO SAMPLES HAVE BEEN RECEIVED AND NO UNITS ARE AVAILABLE IN B. BRAUN SURGICAL, S.A. WE HAVE ONLY REVIEWED THE BATCH MANUFACTURING RECORD AND THE RESULTS DURING THE PROCESS FULFILL USP/EP AND B. BRAUN SURGICAL REQUIREMENTS. FINAL CONCLUSION: WITHOUT SAMPLES WE ARE NOT IN POSITION OF STUDYING IF THE AFFECTED PRODUCT DOES NOT FULFIL THE SPECIFICATIONS. IN CONSEQUENCE, A PROPER ANALYSIS CANNOT BE DONE AND THE CASE IS NOT CONFIRMED DUE TO LACK OF EVIDENCE. NEVERTHELESS, WE TAKE NOTE OF THIS INCIDENCE AND IF ANY SAMPLE IS RECEIVED IN THE FUTURE, WE WILL RE-OPEN THE CASE AND ANALYSE IT. PLEASE NOTE THAT WHEN NO SAMPLES ARE RECEIVED OUR ANALYSIS IS VERY LIMITED. WE REGRET ANY INCONVENIENCE THIS ISSUE MAY HAVE CAUSED AND THANK YOU FOR YOUR COLLABORATION. ACTIONS ON PRODUCT DISTRIBUTED OF THIS REFERENCE/BATCH: BASED ON THE CONCLUSION DERIVED FROM INVESTIGATION, IT IS NOT REQUIRED TO MAKE ACTIONS IN DISTRIBUTED PRODUCT. CORRECTIVE/PREVENTIVE ACTIONS: ACCORDING TO OUR INTERNAL PROCEDURES, THERE IS NO NEED TO ESTABLISH CORRECTIVE OR PREVENTIVE ACTIONS. NEVERTHELESS, THIS COMPLAINT IS RECORDED FOR TRENDING ANALYSIS TO ASSESS IF ACTIONS ARE NEEDED IN THE FUTURE.
K170661. REPORTED DEVICE NOT MARKETED IN THE U.S., HOWEVER, SIMILAR DEVICES OR DEVICES THAT SHARE COMPONENTS, RAW MATERIALS, PROCESS METHODS OR OTHER TECHNOLOGICAL CHARACTERISTICS ARE REGISTERED WITHIN THE U.S. IF ADDITIONAL INFORMATION BECOMES AVAILABLE A FOLLOW-UP REPORT WILL BE SUBMITTED.
IT WAS REPORTED THAT THERE WAS AN ISSUE WITH NOVOSYN QUICK UNDYED SUTURE. THE CLIENT REPORTED THAT THE THREAD BREAKS NEAR THE NEEDLE END. NO MORE DATA HAS BEEN PROVIDED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 689932 | NOVOSYN QUICK UNDY 5/0(1)70CM DS16(M)DDP | SYNTHETIC ABSORBABLE BRAIDED S | GAM | B. BRAUN SURGICAL, S.A. | C3046212 | 118261 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |