FDA Adverse Event Malfunction Summary report: N

LEAD

MDR report key: 10171257 · Received June 18, 2020

Report

Report Number
2182207-2020-00378
Event Type
Malfunction
Date Received
June 18, 2020
Date of Event
May 4, 2020
Report Date
June 18, 2020
Manufacturer
MEDTRONIC NEUROMODULATION
Product Code
MHY
PMA / PMN Number
P960009
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

THIS VALUE IS THE AVERAGE AGE OF THE PATIENTS REPORTED IN THE ARTICLE AS SPECIFIC PATIENTS COULD NOT BE IDENTIFIED. THIS VALUE REFLECTS THE GENDER OF THE MAJORITY OF THE PATIENTS REPORTED IN THE ARTICLE AS SPECIFIC PATIENTS COULD NOT BE IDENTIFIED. DATE OF EVENT: PLEASE NOTE THAT THIS DATE IS BASED OFF OF THE DATE OF PUBLICATION OF THE ARTICLE AS THE EVENT DATES WERE NOT PROVIDED IN THE PUBLISHED LITERATURE. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

TAKASHI TSUBOIA, JANINE LEMOS MELO LOBO JOFILI LOPESA, BHAVANA PATELA, JOSEPH LEGACYA, KATHRYN MOOREA, ROBERT S. EISINGERA, LEONARDO ALMEIDAA, KELLY D. FOOTEC, MICHAEL S. OKUNA, ADOLFO RAMIREZ-ZAMORA OBJECTIVE: WE AIMED TO EXPLORE THE DIFFERENCES IN MOTOR SYMPTOMS AND QUALITY OF LIFE (QOL) OUTCOMES FOLLOWING BILATERAL GLOBUS PALLIDUS INTERNUS DEEP BRAIN STIMULATION (GPI DBS), ACROSS WELL-DEFINED MOTOR SUBTYPES OF PARKINSON'S DISEASE (PD), TO IMPROVE CLINICAL DECISION MAKING. METHODS: THIS SINGLE-CENTER RETROSPECTIVE STUDY INVESTIGATED BILATERAL GPI DBS OUTCOMES IN 65 PD PATIENTS. OUTCOME MEASURES INCLUDED THE UNIFIED PARKINSON'S DISEASE RATING SCALE (UPDRS) AND PARKINSON'S DISEASE QUESTIONNAIRE (PDQ-39) BEFORE AND ONE YEAR AFTER SURGERY. OUTCOMES WERE COMPARED BETWEEN THE TREMOR DOMINANT (TD) AND POSTURAL INSTABILITY AND GAIT DIFFICULTY (PIGD) SUBTYPES AND BETWEEN THE TD AND AKINETIC-RIGID (AR) SUBTYPES. RESULTS: FOR THE ENTIRE COHORT, MOTOR FUNCTION (UPDRS III) IN THE OFF-MEDICATION STATE, MOTOR COMPLICATIONS (UPDRS IV), ACTIVITIES OF DAILY LIVING (ADL, UPDRS II), AND THE ADL AND DISCOMFORT DOMAINS OF PDQ-39 SIGNIFICANTLY IMPROVED ONE YEAR FOLLOWING GPI IMPLANTATION COMPARED TO BASELINE (EFFECT SIZE = 1.32, 1.15, 0.25, 0.45, AND 0.34, RESPECTIVELY). GPI DBS IMPROVED THE OFF-MEDICATION UPDRS III SCORES REGARDLESS OF THE MOTOR SUBTYPES. HOWEVER, COMPARED TO THE PIGD AND AR PATIENTS, THE TD PATIENTS SHOWED GREATER IMPROVEMENT IN OVERALL UPDRS III POSTOPERATIVELY PRIMARILY DUE TO GREATER TREMOR IMPROVEMENT IN THE OFF-MEDICATION STATE. THE OUTCOMES IN AKINESIA, RIGIDITY, AXIAL SYMPTOMS AND QOL WERE SIMILAR AMONG ALL SUBTYPES. CONCLUSION: BILATERAL GPI DBS WAS EFFECTIVE FOR ADVANCED PD PATIENTS REGARDLESS OF MOTOR SUBTYPES. GREATER TREMOR IMPROVEMENT IN THE TD PATIENTS ACCOUNTED FOR GREATER OFF-MEDICATION MOTOR IMPROVEMENT. LONGER-TERM GPI DBS OUTCOMES ACROSS DIFFERENT MOTOR SUBTYPES AND BRAIN TARGETS SHOULD BE FURTHER STUDIED. PLI 2: IT WAS REPORTED THAT FOUR PATIENTS EXPERIENCED LEAD FRACTURES. IT WAS NOT POSSIBLE TO ASCERTAIN ANY ADDITIONAL SPECIFIC DEVICE INFORMATION FROM THE ARTICLE OR TO MATCH THE REPORTED EVENT WITH ANY PREVIOUSLY REPORTED EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
635118 LEAD STIMULATOR, ELECTRICAL, IMPLANTED, FOR PARKINSONIAN TREMOR MHY MEDTRONIC NEUROMODULATION NEU_UNKNOWN_LEAD UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1 63 YR