FDA Adverse Event Malfunction Summary report: N

PROTEUSPLUS

MDR report key: 10168195 · Received June 18, 2020

Report

Report Number
3000256071-2020-00003
Event Type
Malfunction
Date Received
June 18, 2020
Date of Event
May 20, 2020
Report Date
May 20, 2020
Manufacturer
IBA (ION BEAM APPLICATIONS)
Product Code
LHN
UDI-DI
05404013814015
PMA / PMN Number
K163500
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

EVALUATION SUMMARY IS PROVIDED IN SECTION B5 (DESCRIBE EVENT OR PROBLEM).

Description of Event or Problem · 0

EVENT DESCRIPTION (FROM INITIAL REPORT) : ON (B)(6) 2020, DURING THE PREPARATION FOR A TREATMENT, AN ABORT OCCURRED WHEN AN ABNORMAL BEAM WAS DETECTED. IT WAS NOT POSSIBLE TO RESUME MANUALLY THE PARTIAL TREATMENT FROM DCEU (DOSIMETRY COUNTER ELECTRONIC UNIT) VALUE, BUT THE TPS (TREATMENT PLANNING SYSTEM) WAS USED TO MAKE A SINGLE PRESCRIBED BEAM OF THE NORMAL BEAM SKIPPING THE ALREADY DELIVERED SPOTS. PRELIMINARY ANALYSIS (FROM INITIAL REPORT) : THE ISSUE IS UNDER ANALYSIS AND IS REPORTED PREVENTIVELY. SUPPLEMENTAL REPORT WILL INCLUDE ANALYSIS OF THE ISSUE. EVALUATION SUMMARY (SUPPLEMENTAL REPORT): DURING THE ANALYSIS OF THE (B)(6) 2020 EVENT, IBA IDENTIFIED AN ISSUE WITH THE PROTON THERAPY SYSTEM SOFTWARE VERSIONS PTS-12.0.0, PTS- 12.0.1 AND PTS-12.0.1.1. WHEN USING THE IBA PROTON THERAPY SYSTEM IN COMBINATION WITH AN OIS IN DEVICE CENTRIC MODE, IF AN IRRADIATION ABORT OCCURS RESULTING IN A CORRUPTED OR UNAVAILABLE TREATMENT RECORD, THE CURRENT PTS SOFTWARE DOES NOT PERMIT IN A STRAIGHFORWARD WAY, THE DELIVERY OF THE ABORTED BEAM THROUGH THE OIS. IBA INITIATED A MEDICAL DEVICE CORRECTION (SEE RECALL REPORT IBA REF. PR-115141 - RES 86076 / Z-2715-2020). PLEASE REFER TO THE RECALL REPORT FOR ADDITIONAL DETAILS.

Description of Event or Problem · 1

EVENT DESCRIPTION : ON (B)(6) 2020, DURING THE PREPARATION FOR A TREATMENT, AN ABORT OCCURRED WHEN AN ABNORMAL BEAM WAS DETECTED. IT WAS NOT POSSIBLE TO RESUME MANUALLY THE PARTIAL TREATMENT FROM DCEU (DOSIMETRY COUNTER ELECTRONIC UNIT) VALUE, BUT THE TPS (TREATMENT PLANNING SYSTEM) WAS USED TO MAKE A SINGLE PRESCRIBED BEAM OF THE NORMAL BEAM SKIPPING THE ALREADY DELIVERED SPOTS. PRELIMINARY ANALYSIS : THE ISSUE IS UNDER ANALYSIS AND IS REPORTED PREVENTIVELY. SUPPLEMENTAL REPORT WILL INCLUDE ANALYSIS OF THE ISSUE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
632473 PROTEUSPLUS PROTON THERAPY SYSTEM LHN IBA (ION BEAM APPLICATIONS) PROTEUS 235 05404013814015

Patients

Seq Age Sex Outcome Treatment
1 Other