FDA Adverse Event Malfunction Summary report: N

SYRINGE 0.5ML 29GA 1/2IN 7BAG 420CAS JP

MDR report key: 10106495 · Received June 1, 2020

Report

Report Number
1920898-2020-00595
Event Type
Malfunction
Date Received
June 1, 2020
Date of Event
May 11, 2020
Report Date
May 12, 2020
Manufacturer
BD MEDICAL - DIABETES CARE
Product Code
FMF
PMA / PMN Number
NA
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

INVESTIGATION SUMMARY: LEVEL A INVESTIGATION - COMPLAINT EVALUATION / COMPLAINT HISTORY CHECK FOR THE EVENT(S) THAT OCCURRED. SEVERITY: S_1__; OCCURRENCE: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 1ST RELATED COMPLAINT FOR NEEDLE HUB SEPARATES ON LOT # 9231037. INVESTIGATION SUMMARY: CUSTOMER RETURNED PHOTOS OF A 1/2CC SYRINGE. CUSTOMER STATES THAT HUBS WERE DETACHED FROM THE BARRELS. THE PHOTOS WERE EXAMINED AND EXHIBITED THE HUB-NEEDLE/SHIELD ASSEMBLY SEPARATED FROM THE BARREL. MANUFACTURING ((B)(4)) WILL BE NOTIFIED OF THIS ISSUE. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR BATCH# 9252463. ALL INSPECTIONS AND CHALLENGES WERE PERFORMED PER THE APPLICABLE OPERATIONS QC SPECIFICATIONS. THERE WAS ONE (1) NOTIFICATION [(B)(4)] NOTED THAT DID NOT PERTAIN TO THE COMPLAINT. INVESTIGATION CONCLUSION: BASED ON THE SAMPLES AND/OR PHOTO(S) RECEIVED THE INVESTIGATION CONCLUDED: CONFIRMED: BD WAS ABLE TO DUPLICATE OR CONFIRM THE CUSTOMER¿S INDICATED FAILURE. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS. ROOT CAUSE DESCRIPTION: AS PER INVESTIGATION COMPLETED BY MANUFACTURING UNDER INVESTIGATION CHILD (B)(4), "ON 20MAY2020, (B)(4) RECEIVED PHOTO COMPLAINT. A VISUAL EVALUATION OF PHOTO FOUND (1) SYRINGE WITH NO NEEDLE ASSEMBLY ATTACHED. THERE DID NOT APPEAR TO BE ANY DAMAGE TO THE TIP OF THE BARREL, OR ANYWHERE ON THE SYRINGE. PROCESS SUMMARY: AUTOMATIC SYRINGE ASSEMBLY MACHINE, WHICH FEEDS 1/2CC, SYRINGE COMPONENTS (BARREL, STOPPER, PLUNGER, NEEDLE ASSEMBLY & CAP) AND ASSEMBLES THESE COMPONENTS. THIS MACHINE CONSISTS OF A BARREL CLEANING DIAL, LUBRICATION DIAL, PLUNGER/STOPPER ASSEMBLY DIAL, SYRINGE ASSEMBLY DIAL, AND VARIOUS INSPECTIONS AND TRANSFER DIALS. ROOT CAUSE: L2L DISPATCH #77301 WAS CREATED FOR HIGH HUBS. DEBRIS WAS COLLECTED ON THE DIAL. CORRECTIVE ACTION: CLEANED THE DEBRIS OUT OF THE DIAL. RATIONALE: BASED ON THE INVESTIGATION, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME.

Description of Event or Problem · 1

IT WAS REPORTED THAT SYRINGE 0.5ML 29GA 1/2IN 7BAG 420CAS JP HUB DETACHED BEFORE USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: A HUB WAS DETACHED WHEN REMOVING THE SHIELD.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
570744 SYRINGE 0.5ML 29GA 1/2IN 7BAG 420CAS JP SYRINGE FMF BD MEDICAL - DIABETES CARE 9231037

Patients

Seq Age Sex Outcome Treatment
1 Other