FDA Adverse Event Malfunction Summary report: N

PERSONAL CATHETER¿ INTERMITTENT CATHETER

MDR report key: 10006323 · Received April 28, 2020

Report

Report Number
1018233-2020-02888
Event Type
Malfunction
Date Received
April 28, 2020
Report Date
May 15, 2020
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
KOD
UDI-DI
00801741068942
PMA / PMN Number
K000723
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE REPORTED EVENT COULD NOT BE CONFIRMED AS NO SAMPLE WAS RETURNED FOR EVALUATION. A POTENTIAL ROOT CAUSE FOR THIS FAILURE COULD BE "THERMOCOUPLE OOC." THE LOT NUMBER IS UNKNOWN; THEREFORE, THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: "FOR UROLOGICAL USE ONLY. URINARY CATHETERS ARE INTENDED FOR USE FOR BLADDER MANAGEMENT INCLUDING URINE DRAINAGE, COLLECTION AND MEASUREMENT. THE DEVICES ARE PASSED TO THE URINARY BLADDER VIA THE URETHRA. WARNINGS: THIS IS A SINGLE USE DEVICE. DO NOT REUSE. REUSE OF A SINGLE USE DEVICE INCREASES THE RISK OF CATHETER ACQUIRED URINARY TRACT INFECTIONS. HOW TO PREPARE AND USE YOUR URINARY CATHETER 1. WASH YOUR HANDS THOROUGHLY WITH SOAP AND WATER. 2. PEEL OPEN THE PACK AT THE FUNNEL END TO EXPOSE APPROXIMATELY 2¿- 4¿ OF THE CATHETER. DON¿T REMOVE THE CATHETER YET. 3. WASH THE AREA AROUND THE MEATUS BEFORE CATHETERIZING. 4. WASH YOUR HANDS AGAIN. 5. USING THE CATHETER: WITH SURE-GRIP¿ SLEEVE: A. HOLD THE SURE-GRIP¿ SLEEVE WITH YOUR DOMINANT HAND AND SQUEEZE IT TO HOLD THE CATHETER SHAFT AS YOU REMOVE THE CATHETER FROM THE PACK. B. NEXT, HOLD THE CATHETER FUNNEL ABOVE THE SURE-GRIP¿ SLEEVE WITH YOUR OTHER HAND AND SLIDE THE SURE-GRIP¿ SLEEVE DOWN THE SHAFT, STOPPING AT ABOUT 6¿ FROM THE TIP. RELEASE THE FUNNEL. C. USING THE SURE-GRIP¿ SLEEVE TO HOLD THE CATHETER FIRMLY, LUBRICATE CATHETER TIP WITH LUBRICATING GEL. D. WHILE GRIPPING THE CATHETER WITH THE SURE-GRIP¿ SLEEVE, GENTLY PASS THE TIP OF THE CATHETER INTO YOUR URETHRA UNTIL THE SURE-GRIP¿ SLEEVE NEARS THE MEATUS. IF THERE IS NO URINE FLOW, LOOSEN THE TENSION ON THE SURE-GRIP¿ SLEEVE TO ALLOW IT TO SLIDE BACK TOWARDS THE FUNNEL END. RE-GRIP SURE-GRIP¿ SLEEVE AND CONTINUE TO INSERT THE CATHETER INTO THE URETHRA. REPEAT UNTIL URINE STARTS TO FLOW. WITHOUT SURE-GRIP¿ SLEEVE: A. REMOVE THE CATHETER FROM THE PACK. B. LUBRICATE THE CATHETER TIP WITH LUBRICATING GEL. C. GENTLY PASS THE TIP OF THE CATHETER INTO YOUR URETHRA AND ADVANCE THE CATHETER UNTIL URINE STARTS TO FLOW. 6. TRY TO KEEP THE CATHETER STEADY UNTIL URINE STOPS FLOWING. WHEN URINE STOPS FLOWING, SLOWLY WITHDRAW THE CATHETER, STOPPING IF FLOW STARTS AGAIN, UNTIL THE LAST FEW DROPS HAVE DRAINED. 7. FINISH BY DISPOSING OF THE CATHETER AND ITS PACKAGING. 8. WASH YOUR HANDS WITH SOAP AND WATER." H11:SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD. H3 OTHER TEXT : THE DEVICE WAS NOT RETURNED.

Description of Event or Problem · 0

IT WAS REPORTED THAT TWO CATHETERS HAD NO EYELETS.

Additional Manufacturer Narrative · 1

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT TWO CATHETERS HAD NO EYELETS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
471702 PERSONAL CATHETER¿ INTERMITTENT CATHETER INTERMITTENT CATHETER KOD C.R. BARD, INC. (COVINGTON) -1018233 61312 UNK 00801741068942

Patients

Seq Age Sex Outcome Treatment
1