Additional Manufacturer Narrative · 1

(B)(4). DATE OF EVENT: UNKNOWN. BATCH # UNKNOWN. THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED.

Description of Event or Problem · 1

IT WAS REPORTED VIA JOURNAL ARTICLE: TITLE: THE IMMEDIATE RESULTS OF APPLYING VARIOUS WAYS OF FORMING ILEOTRANSVERSE ANASTOMOSIS IN RIGHT HEMICOLECTOMY IN ONCOLOGY PRACTICE. AUTHORS: GLUSHKOV E.A., NIKITIN N.A., IVANOV A.D., KISLICHKO S.A. CITATION: VYATKA MEDICAL HERALD, NO. 3 (63), 2019: 22-26. DOI: 10.24411/2220-7880-2019-10005. THE OBJECTIVE OF THIS STUDY WAS TO INTRODUCE THE INVAGINATION ILEOTRANSVERSE ANASTOMOSIS (ITA) PROPOSED BY NIKITIN INTO THE PRACTICE OF PERFORMING RIGHT-SIDED HEMICOLECTOMY IN PLANNED ONCOLOGY AND TO STUDY THE IMMEDIATE RESULTS OF ITS USE AS COMPARED TO AN END-TO-SIDE TRANSVERSE ITA AND A LONGITUDINAL LATERAL ITA. THE STUDY INCLUDED 73 PATIENTS (AGE RANGE:43 TO 83 YEARS) WITH CONFIRMED ADENOCARCINOMA OF THE RIGHT HALF OF THE COLON IN STAGES I-IV, WHO UNDERWENT TREATMENT OVER THE PERIOD EXTENDING FROM 2017 THROUGH 2018 AND WHO WERE REPRESENTED BY THREE GROUPS AS A FUNCTION OF THE ITA FORMATION METHOD USED: NIKITIN'S ITA GROUP INCLUDED 22 OBSERVATIONS (10 MALE AND 12 FEMALE; AGE: 67±8.6 YEARS; BMI: 23.2±4.4 KG/CM2); TRANS-VERSE END-TO-SIDE ITA GROUP INCLUDED 21 OBSERVATIONS (13 MALE AND 8 FEMALE; AGE: 64±7.6 YEARS; BMI: 26.7±4.8 KG/CM2); AND LONGITUDINAL LATERAL ITA GROUP INCLUDED 30 OBSERVATIONS (17 MALE AND 13 FEMALE; AGE: 65±9.4 YEARS; BMI: 25.9±5.1 KG/CM2). DURING THE PROCEDURE, THE SURGICAL RELEASE OF THE RIGHT HALF OF THE COLON AND LYMPHODISSECTION WERE CARRIED OUT USING THE ENSEAL TECHNOLOGY (ENSEAL, BIPOLAR; ETHICON). AN NTLC 75 LINEAR CUTTER (ETHICON) WAS USED DURING INTESTINE TRANSECTION. REPORTED COMPLICATION IN THE NIKITIN'S ITA GROUP INCLUDED IN THE PAIN SYNDROME (N-?) REPORTED COMPLICATION IN THE TRANS-VERSE END-TO-SIDE ITA GROUP INCLUDED IN THE PAIN SYNDROME (N-?). REPORTED COMPLICATIONS IN THE LONGITUDINAL LATERAL ITA GROUP INCLUDED IN THE PAIN SYNDROME (N-?) AND BLEEDING (N-1) IN WHICH THE PATIENT REQUIRED A SECOND SURGICAL INTERVENTION. THE BEST RESULTS WERE OBTAINED IN PATIENTS WITH INVAGINATIONAL ITA ACCORDING TO NIKITIN, THE WORST IN PATIENTS WITH LONGITUDINAL ITA SIDE TO SIDE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
464763 75MM SELECTABLE NEW TLC STAPLE, IMPLANTABLE GDW ETHICON ENDO-SURGERY, LLC. NTLC75 10705036002628

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention