Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: QMG FDA class 3

Shockwave Intravascular Lithotripsy System

View full classification →
Adverse events in period
230
+59% vs. prior period (145)
Deaths reported
42
Recalls in period
0
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
42
38
Injury
146
71
Malfunction
41
36
Other
1
0

Most reported coded problems

Top 15
Product problems
Count
Adverse Event Without Identified Device or Use Problem
129
Material Split, Cut or Torn
40
Detachment of Device or Device Component
15
Difficult to Remove
14
Difficult to Advance
14
Off-Label Use
10
Failure to Deflate
7
Material Rupture
6
Failure to Cycle
4
Inflation Problem
3
Sparking
2
No Apparent Adverse Event
2
Insufficient Device Problem Information
2
Difficult or Delayed Positioning
2
Deformation Due to Compressive Stress
2
Patient problems
Count
Myocardial Infarction
68
No Clinical Signs, Symptoms or Conditions
35
Perforation of Vessels
34
Vascular Dissection
33
Chest Pain
32
Cardiac Arrest
24
Reduced Blood Flow
20
Low Blood Pressure/ Hypotension
14
Ventricular Fibrillation
13
Thrombosis/Thrombus
13
Pericardial Effusion
13
Obstruction/Occlusion
13
Arrhythmia
11
Insufficient Information
8
Foreign Body In Patient
8

Recalls in period

0 total

No recalls recorded for these product codes in the reporting period.

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code QMG, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06).

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-05 22:34 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.