Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: MOF FDA class 2

Guide, Wire, Catheter, Neurovasculature

View full classification →
Adverse events in period
296
+73% vs. prior period (171)
Deaths reported
4
Recalls in period
0
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
4
1
Injury
57
56
Malfunction
235
114

Most reported coded problems

Top 15
Product problems
Count
Fracture
129
Break
82
Peeled/Delaminated
34
Failure to Advance
25
Adverse Event Without Identified Device or Use Problem
11
No Apparent Adverse Event
6
Mechanical Jam
3
Incomplete or Missing Packaging
3
Material Split, Cut or Torn
2
Material Separation
2
Insufficient Device Problem Information
2
Entrapment of Device
2
Packaging Problem
1
Migration
1
Difficult to Insert
1
Patient problems
Count
No Clinical Signs, Symptoms or Conditions
265
Foreign Body In Patient
18
Paralysis
3
Obstruction/Occlusion
3
Speech Disorder
2
Insufficient Information
2
Hypersensitivity/Allergic reaction
2
Fever
2
Visual Disturbances
1
Vasoconstriction
1
Thrombosis/Thrombus
1
Stroke/CVA
1
Stenosis
1
Perforation of Vessels
1
Ischemia Stroke
1

Recalls in period

0 total

No recalls recorded for these product codes in the reporting period.

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code MOF, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06).

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-07 16:23 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.