Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: GCX FDA class 2

Apparatus, Suction, Operating-Room, Wall Vacuum Powered

View full classification →
Adverse events in period
343
+170% vs. prior period (127)
Deaths reported
5
Recalls in period
3
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
5
2
Injury
12
12
Malfunction
324
113
Other
2
0

Most reported coded problems

Top 15
Product problems
Count
Smoking
68
Leak/Splash
43
Overheating of Device
42
Device Contaminated During Manufacture or Shipping
40
Fluid/Blood Leak
34
Temperature Problem
33
Decrease in Pressure
29
Crack
20
Noise, Audible
14
Mechanical Problem
14
Delivered as Unsterile Product
14
Break
12
Pressure Problem
9
Suction Problem
8
Detachment of Device or Device Component
8
Patient problems
Count
No Clinical Signs, Symptoms or Conditions
306
Insufficient Information
32
Foreign Body In Patient
3
Hemorrhage/Blood Loss/Bleeding
2
Dysphagia/ Odynophagia
2
Cough
2
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
2
Weight Changes
1
Unspecified Respiratory Problem
1
Skin Inflammation/ Irritation
1
Skin Burning Sensation
1
Pulmonary Edema
1
Pain
1
Inflammation
1
Ear injury
1

Recalls in period

3 total
FDA enforcement classification: Class II: 4
Date
Recalling firm
Status
2025-12-26
Open, Classified
2025-06-18
Open, Classified
2024-11-19
Open, Classified

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code GCX, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06).

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-05 22:17 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.