Product Code: FXX FDA class 2

Mask, Surgical

View full classification →
Adverse events in period
41
0% vs. prior period (41)
Deaths reported
0
Recalls in period
2
Class I enforcement
0

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Injury
24
20
Malfunction
17
21

Your device vs. all similar devices

Name-matched — verify
name-matched — verify before use Healthdyne Cardiovascular Inc.

18 of 41 adverse events in the period (43.9%) matched the device/manufacturer names above. Matching is by name within the reported MAUDE fields — it can miss differently-spelled reports and include similarly-named devices. Verify individual reports before citing them in a PSUR.

Injury 11
Malfunction 7

Most reported coded problems

Top 15
Product problems
Count
Adverse Event Without Identified Device or Use Problem
9
Patient Device Interaction Problem
4
Patient-Device Incompatibility
3
Insufficient Device Problem Information
3
Device Emits Odor
3
Break
3
Protective Measures Problem
2
Material Puncture/Hole
2
Contamination
2
Component Incompatible
2
Product Quality Problem
1
Material Protrusion/Extrusion
1
Material Opacification
1
Material Integrity Problem
1
Device Dislodged or Dislocated
1
Patient problems
Count
No Clinical Signs, Symptoms or Conditions
12
Rash
9
Skin Inflammation/ Irritation
7
Itching Sensation
5
Hypersensitivity/Allergic reaction
5
Eye Injury
3
Insufficient Information
2
Asthma
2
Unspecified Skin and Subcutaneous Tissue Problem
1
Skin Discoloration
1
Skin Burning Sensation
1
Local Reaction
1
Irritability
1
Foreign Body In Patient
1
Eye Pain
1

Recalls in period

2 total
FDA enforcement classification: Class II: 2
Date
Recalling firm
Status
2024-11-08
O & M HALYARD, INC. name match
Open, Classified
2024-11-08
O & M HALYARD, INC. name match
Open, Classified

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code FXX, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06). Device-level attribution used name matching against “Healthdyne Cardiovascular”, “Inc.” — name matches are indicative, not authoritative.

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-19 10:29 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.