Tool · Post-Market Surveillance

PSUR Report

The vigilance database section of your PSUR, generated in seconds: FDA MAUDE adverse event trends, recalls, and enforcement classifications for your device and similar devices — with the documented, reproducible methodology auditors ask for.

Period
from
to
Leave empty for the last 24 months

Reporting period 2024-072026-06 · FDA data refreshed ~monthly

Product Code: DWF FDA class 2

Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass

View full classification →
Adverse events in period
1,798
+129% vs. prior period (784)
Deaths reported
39
Recalls in period
18
Class I enforcement
4

Adverse events per month

2024-07 – 2026-06
Loading...

Events by type

Period vs. prior period
Loading...
Event type
Period
Prior
Death
39
29
Injury
141
142
Malfunction
1,618
613

Your device vs. all similar devices

Name-matched — verify
name-matched — verify before use AngioDynamics Inc.

53 of 1,798 adverse events in the period (2.9%) matched the device/manufacturer names above. Matching is by name within the reported MAUDE fields — it can miss differently-spelled reports and include similarly-named devices. Verify individual reports before citing them in a PSUR.

Death 3
Injury 7
Malfunction 43

Most reported coded problems

Top 15
Product problems
Count
Material Separation
454
Delivered as Unsterile Product
240
Mechanical Problem
236
Material Deformation
205
Fluid/Blood Leak
184
Contamination
171
Crack
108
Material Puncture/Hole
102
Obstruction of Flow
100
Misassembled During Installation
64
Adverse Event Without Identified Device or Use Problem
58
Device Markings/Labelling Problem
48
Break
43
Air/Gas in Device
40
Difficult to Open or Close
37
Patient problems
Count
No Clinical Signs, Symptoms or Conditions
1,591
Hemorrhage/Blood Loss/Bleeding
121
Insufficient Information
50
Stroke/CVA
28
Foreign Body In Patient
16
Renal Failure
14
Perforation of Vessels
12
Sepsis
10
Atrial Fibrillation
10
Ischemia
8
Cardiac Arrest
8
Vascular Dissection
7
Low Blood Pressure/ Hypotension
7
Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
7
Aortic dissection
7

Recalls in period

18 total
FDA enforcement classification: Class I: 4 Class II: 14
Date
Recalling firm
Status
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2026-04-21
Open, Classified
2025-08-06
Open, Classified
2025-08-06
Open, Classified
2025-08-06
Open, Classified
2025-02-05
Open, Classified
2024-12-12
Open, Classified
2024-12-12
Open, Classified
2024-12-12
Open, Classified
2024-10-03
Open, Classified
2024-07-09
Open, Classified

Adverse events by year

Loading...

Methodology & data provenance

For your PSUR appendix

Search protocol: FDA MAUDE adverse event reports, FDA device recalls, and FDA enforcement reports (openFDA datasets) were queried for product code DWF, reporting period 2024-07 to 2026-06 (prior comparison period 2022-07 to 2024-06). Device-level attribution used name matching against “AngioDynamics”, “Inc.” — name matches are indicative, not authoritative.

Data coverage: adverse event data for these product codes extends through 2026-05. Source openFDA export dated 2026-06-30. Recall records with missing or implausible initiation dates (0 for these codes) are excluded from period counts.

Generated: 2026-07-19 10:53 UTC by BEUDAMED (beudamed.com/fda/psur-report). Dataset sizes: 25,039,198 adverse events, 58,607 recalls, 39,365 enforcement reports.

PSUR database searches, explained

Under the EU MDR, manufacturers must produce a Periodic Safety Update Report (PSUR) (Class IIa and above; a PMS report for Class I) on a defined schedule. A required part of that report is a survey of publicly available vigilance data — most importantly the FDA's MAUDE adverse event database and FDA recall records — covering both your own device and similar devices on the market (the "state of the art").

Doing this by hand means repeated MAUDE queries, manual export, deduplication, and trending — hours of work per report, repeated every reporting period. This tool runs the same search protocol in seconds and documents it: which datasets were queried, with which filters, when, and with what coverage — so the search is reproducible, which is exactly what a Notified Body auditor wants to see.

Event counts are grouped by the FDA's reported event type (death, injury, malfunction). Name-based device matching is clearly labeled as indicative: only you can confirm whether a specific MAUDE report concerns your device. Recall records with implausible dates are excluded and the exclusion is disclosed. All data is from the official openFDA datasets and refreshed approximately monthly.