View 10000 FDA Device Enforcement Reports on BEUDAMED, the Better Database on Medical Devices. These records compile FDA actions such as recalls, safety alerts, market withdrawals, and warning letters related to medical devices regulated in the United States. Each entry lists device identifiers, manufacturer information, enforcement dates, and the reason for the action to support quick assessment.

FDA Device Enforcement Reports help clinicians, manufacturers, and health-system buyers assess device safety and regulatory status. Use BEUDAMED to monitor trends, compare enforcement activity across device types, and export data for quality and compliance reviews. Regular review of enforcement reports supports post-market surveillance and informed procurement decisions.

Burlington Medical, Protective Sleeves.

FDA Enforcement
Class II ·Ongoing·Burlington Medical, LLC·April 8, 2026

WHILL Model F, with software versions before HMI: 2.23 / MC: 1.05; the device is an indoor/outdoor, foldable battery-operated 2-wheel drive (rear-wheel drive) powered wheelchair.

FDA Enforcement
Class I ·Ongoing·WHILL, INC.·May 6, 2026

Brand Name: Olympus ShockPulse-SE Lithotripsy System with Generator Product Name: ShockPulse-SE Lithotripsy System - Reuseable Probes Model/Catalog Number: SPL-SR, contains generator SPL-G Product Description: An assembly of devices that uses a combination of, or individually applied, pneumatically-created ballistic shock waves and ultrasonic waves for the intracorporeal fragmentation of stones (calculi) in the urinary tract (i.e., kidney, ureter, and bladder) for their removal. It typically includes a pressure and power regulator/control unit, handpieces, and two types of probes of various sizes. The probes are attached to the two handpieces which are connected to the control unit that supplies the energy for both the pneumatic and ultrasonic functions. Energy is applied to a calculus which is fragmented in situ and removed via a suction system facilitated by the lithotripsy system.

FDA Enforcement
Class II ·Ongoing·Olympus Corporation of the Americas·March 11, 2026

LeadCare¿ Plus Blood Lead Test Kit; Catalog Number: 82-0004; The LeadCare¿ Plus kit is provided with the following materials: " Sensors (4 containers of 24 each; 96 tests) " Treatment Reagent Tubes (4 packages of 24 each; 96 tests) " Calibration Button (1 @) " Lead Control Level 1 (1 @ 2 mL) " Lead Control Level 2 (1 @ 2 mL)

FDA Enforcement
Class II ·Ongoing·Magellan Diagnostics, Inc.·April 29, 2026

Medline Kits: 1) PICC TRAY, Model Number: DYNJ41648A

FDA Enforcement
Class II ·Ongoing·Medline Industries, LP·April 29, 2026

Multi-parameter Command Module, Model 91496, optioned with Masimo or Nellcor

FDA Enforcement
Class II ·Ongoing·Spacelabs Healthcare, Inc.·April 15, 2026

HCS - Headless Compression Screw System, Headless Compression Screw, Cannulated; Article Numbers: 31207-10, 31207-12, 31207-14, 31207-16, 31207-18, 31207-20, 31207-24, 31207-26, 31207-28, 31207-30, 31257-12, 31257-14, 31257-16, 31257-18, 31257-20, 31257-22, 31257-24, 31257-28, 31257-30, 31307-18, 31307-32, 31307-34, 31307-36, 31307-38, 31358-30, 31437-30, 31437-38, 31437-40, 31437-50, 31757-100, 31757-120, 31757-45, 31757-80, 31757-85, 31757-90.

FDA Enforcement
Class II ·Ongoing·I.T.S. GmbH·April 1, 2026

MiniMed 700G Insulin Pump (MMT-1801, MMT-1805, MMT-1850, MMT-1851)

FDA Enforcement
Class II ·Ongoing·Medtronic MiniMed, Inc.·April 8, 2026

OXOID MICROBACT IDENTIFICATION KITS, Listeria 12L Kit, 20 Tests; Listeria identification sysystem

FDA Enforcement
Class II ·Ongoing·Oxoid Australia Pty Limited·April 8, 2026

Arrowg+ard Blue¿ MAC" Two-Lumen Central Venous Access Kit for use with 7.5 - 8 Fr. Catheters REF ASK-21142-DMC UDI code: (01)10801902218930(17)270630(11)251211(10)33F25M0671 The MAC Multi-Lumen Central Venous Access Device with Arrowg+ard Blue technology permits short-term (<30 days) venous access and catheter introduction to the central circulation. It may be inserted into the jugular, subclavian, or femoral veins. The Arrowg+ard technology is intended to help provide protection against catheterrelated infections. Clinical data have not been collected that demonstrate the use of the Arrowg+ard antimicrobial surface in decreasing catheter-related infections for this device. It is not intended to be used as a treatment for existing infections, nor is it indicated for long-term use.

FDA Enforcement
Class II ·Ongoing·ARROW INTERNATIONAL, LLC·April 29, 2026