Tissue saturation oximeters
Basic Information
- Primary DI
- 06972772850043
- Basic UDI-DI Code
- 697277285001ND
- Reference
- 06972772850043
- Device Types
- None provided
- Regulation
- Eu Mdr
- Classification
- Eu Md Class 2a
- Status
- On The Market
- Manufacturer
- Suzhou Engin Bio-medical Electronics Co.,Ltd.
Additional Description
The ECO-N17 series product manufactured by Suzhou Engin Bio-medical Electronics Co., Ltd. is used to monitor blood oxygen parameters of the local tissue, including the tissue oxygen index (TOI), the tissue hemoglobin concentration index (THI), as well as the change of deoxyhemoglobin (Hb) concentration, oxyhemoglobin (HbO2) concentration and total hemoglobin (tHb) concentration in the local tissue compared to their initial values, i.e., ΔCHb, ΔCHbO2 and ΔCtHb. The Tissue Saturation Oximeters controls the alternate emission of three wavelengths of light by LED, measures the emergent light signal after tissue attenuation, and calculates blood oxygen parameters of the tissue through SRS. The product has high sensitivity and stable and reliable performance. The Tissue Saturation Oximeters is a non-invasive device that measures absolute tissue oxygen saturation under the Sensor. The sensor uses three wavelengths to measure light absorption of tissue. It is allowing the clinician to continuously and accurately determine absolute levels of blood oxygenation saturation in the tissue (StO2). The Tissue Saturation Oximeters consists of displayed unit, testing device with communication cable, disposable sensor, battery, power adapter, and power cable. Display unit: The display unit adopts the capacitive touch screen to display the product monitoring interface, provides specifications of four-channel, dual-channel and single-channel, and is equipped with the USB interface, Internet access and serial port, etc. Testing device: The testing unit is used in combination with the display unit, and provides specifications of dual-channel and single-channel. The Tissue Saturation Oximeters achieves its intended use in combination with Tissue saturation oximeter sensors which is non-sterile, single use device.
CND Nomenclature Codes
| Code | Description |
|---|---|
| Z1203020202 | TRANSPORTABLE/PORTABLE MULTI–PARAMETER PATIENT MONITORS |
Available In Countries
Related Devices
The Basic UDI-DI associated with this device has 9 devices in total. Below are some other devices sharing the same Basic UDI-DI.
Tissue saturation oximeters
DeviceTissue saturation oximeters
DeviceTissue saturation oximeters
DeviceTissue saturation oximeters
DeviceTissue saturation oximeters
DeviceSimilar Devices
Other on-the-market devices with the same classification (Eu Md Class 2a) and regulation (EU MDR).